Biosensors for in vivo glucose measurement: can we cross the experimental stage

被引:60
作者
Abel, PU
von Woedtke, T
机构
[1] Ernst Moritz Arndt Univ Greifswald, Inst Pathophysiol, D-17495 Karlsburg, Germany
[2] Ernst Moritz Arndt Univ Greifswald, Inst Pharm, D-17487 Greifswald, Germany
[3] Sensor Res Ctr, D-17489 Greifswald, Germany
关键词
biosensor; diffusion membrane; enzyme fixation; biocompatibility; sterilization; biostability; in vivo studies;
D O I
10.1016/S0956-5663(02)00099-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of in vivo working glucose sensors needs two decades, so far. The availability of long term functional implantable biosensors for continuous glucose measurings is a basic preriquisite for the individualized optimum insulin treatment of diabetics. Enzymatic electrochemical sensors are described which realize a functional stability over more than 2 years in vitro, however their function in vivo is limited due to certain bioincompatibility expressed by inflammation of the surrounding tissue, exsudates, and immun reactions. The paper reflects an overview concerning different sensor covering materials used as more or less suitable diffusion membranes. From experimental studies in animals and human volunteers conclusions are drawn for further developmental steps of biosensors for in vivo use and for the appliability of glucose sensors for transient diagnostic purposes and as a basis for glucose controlled therapeutic measures. The results demonstrate that further progress aimed at long term biostability of implanted biosensors needs to solve technological problems and the serial production of sensors with really comparable qualities as a preriquisite for clinical trials. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1059 / 1070
页数:12
相关论文
共 76 条
  • [1] ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
  • [2] Abel P, 1983, Z Med Lab Diagn, V24, P264
  • [3] ABEL P, 1988, HORM METAB RES, V20, P26
  • [4] ABEL P, 1993, IN VIVO CHEM SENSORS, P16
  • [5] ABEL P, 1992, BIOSENSORS FUNDAMENT, P361
  • [6] Abel P. U., 2001, Sensor Review, V21, P297, DOI 10.1108/02602280110406954
  • [7] Stability of immobilized enzymes as biosensors for continuous application in vitro and in vivo
    Abel, PU
    von Woedtke, T
    Schulz, B
    Bergann, T
    Schwock, A
    [J]. JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 1999, 7 (1-4) : 93 - 100
  • [8] Albisser A M, 1977, Horm Metab Res, VSuppl 7, P87
  • [9] ALBISSER AM, 1979, J LAB CLIN MED, V93, P515
  • [10] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696