Diameter variability and microvascular flow resistance

被引:34
作者
Pries, AR
Schonfeld, D
Gaehtgens, P
Kiani, MF
Cokelet, GR
机构
[1] UNIV TENNESSEE, CTR HLTH SCI, DEPT BIOMED ENGN, MEMPHIS, TN 38163 USA
[2] UNIV ROCHESTER, DEPT BIOPHYS, ROCHESTER, NY 14642 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1997年 / 272卷 / 06期
关键词
blood viscosity in vivo; hemodynamics; pressure drop;
D O I
10.1152/ajpheart.1997.272.6.H2716
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Microvessels are known to exhibit irregular shapes, deviating substantially from an idealized cylindrical tube geometry. Such irregularities must be taken into account in calculating microvascular flow resistance and may add to the observation that flow resistance in living microvessels in vivo is about twice that predicted on the basis of tube flow studies in vitro. The present study was aimed at providing a comprehensive database describing the apparent diameter variability for all segments of a complete microvascular network in the rat mesentery and assessing the impact of this variability on segmental flow resistance and the pressure drop across the network. Diameters were estimated by intravital microscopy at axial intervals of 20 mu m along the 546 vessel segments of a mesenteric microvessel network, resulting in 6,319 separate diameter measurements. The amplitude of diameter variations in individual vessel segments decreased from similar to 15% of the mean vessel diameter in the smallest segments (similar to 5 mu m diam) to similar to 5% in the largest segments (similar to 60 mu m diam). Segmental hindrance was estimated to be 10-23% higher than calculated from arithmetic mean diameter, depending on the model used to estimate the hydrodynamically effective segment diameter. The overall pressure drop across the network calculated using a mathematical flow simulation was increased by 7-13.5%. This increase in flow resistance can explain similar to 10% of the observed discrepancy between flow resistance in vivo and in vitro.
引用
收藏
页码:H2716 / H2725
页数:10
相关论文
共 27 条
[1]   SHEAR STRESS-INDUCED REORGANIZATION OF THE SURFACE-TOPOGRAPHY OF LIVING ENDOTHELIAL-CELLS IMAGED BY ATOMIC-FORCE MICROSCOPY [J].
BARBEE, KA ;
DAVIES, PF ;
LAL, R .
CIRCULATION RESEARCH, 1994, 74 (01) :163-171
[2]  
BARBEE KA, 1995, AM J PHYSIOL, V268, pH1756
[3]  
Bevan JA., 1995, FLOW DEPENDENT REGUL
[4]  
COKELET GR, 1992, AM J PHYSIOL, V262, pH1156, DOI 10.1152/ajpheart.1992.262.4.H1156
[5]   FLOW THROUGH TUBES WITH SINUSOIDAL AXIAL VARIATIONS IN DIAMETER [J].
DEIBER, JA ;
SCHOWALTER, WR .
AICHE JOURNAL, 1979, 25 (04) :638-645
[6]   HEPARINASE TREATMENT SUGGESTS A ROLE FOR THE ENDOTHELIAL-CELL GLYCOCALYX IN REGULATION OF CAPILLARY HEMATOCRIT [J].
DESJARDINS, C ;
DULING, BR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (03) :H647-H654
[7]   QUANTIFICATION OF RED-CELL MOVEMENT IN MICROVESSELS - A NEW APPLICATION OF INTERACTIVE COMPUTER-GRAPHICS [J].
ELLIS, CG ;
TYML, K ;
BURGESS, W .
MICROVASCULAR RESEARCH, 1987, 33 (03) :428-432
[8]   MORPHOLOGY OF THE CONSTRICTED ARTERIOLAR WALL - PHYSIOLOGICAL IMPLICATIONS [J].
GREENSMITH, JE ;
DULING, BR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 247 (05) :H687-H698
[9]   EFFECT OF DIAMETER VARIABILITY ALONG A MICROVESSEL SEGMENT ON PRESSURE-DROP [J].
KIANI, MF ;
COKELET, GR ;
SARELIUS, IH .
MICROVASCULAR RESEARCH, 1993, 45 (03) :219-232
[10]   ADDITIONAL PRESSURE-DROP AT A BIFURCATION DUE TO THE PASSAGE OF FLEXIBLE DISKS IN A LARGE-SCALE MODEL [J].
KIANI, MF ;
COKELET, GR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (04) :497-501