Here, we describe the coordinated use of two antibodies with different affinities in a single immunoassay to extend the dynamic range and to enable detection of multiple analytes. The combination of dual antibodies was permitted with a flow-based assay at the antibody concentration below the dissociation constant, enabling affinity to govern the antibody-antigen binding. Both high and low affinity antibodies to estriol were used in combination to extend the range. The binding of each antibody was mutually independent and individually occurred over concentration ranges of 10 pM-1 nM and 100 pM-1 muM. The wide dynamic range of 10 pM-1 muM was thus achieved as summation of the proportional signals to the total binding. When a combination of antibodies toward different antigens was used, it effectively detected multiple analytes within a mixture. In simultaneous analysis of a mixture of estradiol and estriol, the total signal was the sum of the binding signals from anti-estradiol and anti-estriol antibodies. In a further refinement, the individual antibodies were flowed through the flow cell sequentially, allowing the quantification of each binding signal within the combination. With this sequential format, measurement of the individual hormones in the range of 1.6 pM-1 nM was shown. Furthermore, the same flow format was successfully applied to assay estriol and estradiol hormones in mixtures of six related compounds.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 28 条
  • [1] Analysis and occurrence of estrogenic hormones and their glucuronides in surface water and waste water in The Netherlands
    Belfroid, AC
    Van der Horst, A
    Vethaak, AD
    Schäfer, AJ
    Rijs, GBJ
    Wegener, J
    Cofino, WP
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 225 (1-2) : 101 - 108
  • [2] BLAKE C, 1982, CLIN CHEM, V28, P1469
  • [3] Automated kinetic exclusion assays to quantify protein binding interactions in homogeneous solution
    Blake, RC
    Pavlov, AR
    Blake, DA
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 272 (02) : 123 - 134
  • [4] BROWN CR, 1985, CLIN CHEM, V31, P1500
  • [5] Conners K.A., 1987, BINDING CONSTANTS ME
  • [6] DEVELOPING MULTIANALYTE ASSAYS
    EKINS, RP
    CHU, F
    [J]. TRENDS IN BIOTECHNOLOGY, 1994, 12 (03) : 89 - 94
  • [7] DUAL ANALYTE ASSAY BASED ON PARTICLE TYPES OF DIFFERENT SIZE MEASURED BY FLOW-CYTOMETRY
    FRENGEN, J
    LINDMO, T
    PAUS, E
    SCHMID, R
    NUSTAD, K
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 178 (01) : 141 - 151
  • [8] MEASUREMENTS OF THE TRUE AFFINITY CONSTANT IN SOLUTION OF ANTIGEN-ANTIBODY COMPLEXES BY ENZYME-LINKED IMMUNOSORBENT-ASSAY
    FRIGUET, B
    CHAFFOTTE, AF
    DJAVADIOHANIANCE, L
    GOLDBERG, ME
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1985, 77 (02) : 305 - 319
  • [9] GOSLING JP, 1990, CLIN CHEM, V36, P1408
  • [10] GOW SM, 1986, CLIN CHEM, V32, P2191