Reliability and validity of pendulum test measures of spasticity obtained with the Polhemus tracking system from patients with chronic stroke

被引:32
作者
Bohannon, Richard W. [1 ]
Harrison, Steven [1 ]
Kinsella-Shaw, Jeffrey [1 ]
机构
[1] Univ Connecticut, Neag Sch Educ, Dept Phys Therapy, Storrs, CT 06269 USA
来源
JOURNAL OF NEUROENGINEERING AND REHABILITATION | 2009年 / 6卷
关键词
CEREBRAL-PALSY;
D O I
10.1186/1743-0003-6-30
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Spasticity is a common impairment accompanying stroke. Spasticity of the quadriceps femoris muscle can be quantified using the pendulum test. The measurement properties of pendular kinematics captured using a magnetic tracking system has not been studied among patients who have experienced a stroke. Therefore, this study describes the test-retest reliability and known groups and convergent validity of the pendulum test measures obtained with the Polhemus tracking system. Methods: Eight patients with chronic stroke underwent pendulum tests with their affected and unaffected lower limbs, with and without the addition of a 2.2 kg cuff weight at the ankle, using the Polhemus magnetic tracking system. Also measured bilaterally were knee resting angles, Ashworth scores (grades 0-4) of quadriceps femoris muscles, patellar tendon (knee jerk) reflexes (grades 0 4), and isometric knee extension force. Results: Three measures obtained from pendular traces of the affected side were reliable (intraclass correlation coefficient >= .844). Known groups validity was confirmed by demonstration of a significant difference in the measurements between sides. Convergent validity was supported by correlations >= .57 between pendulum test measures and other measures reflective of spasticity. Conclusion: Pendulum test measures obtained with the Polhemus tracking system from the affected side of patients with stroke have good test-retest reliability and both known groups and convergent validity.
引用
收藏
页数:7
相关论文
共 18 条
[1]   Does spasticity contribute to walking dysfunction after stroke? [J].
Ada, L ;
Vattanasilp, W ;
O'Dwyer, NJ ;
Crosbie, J .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1998, 64 (05) :628-635
[2]  
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[3]  
BAJD T, 1984, J BIOMED ENG, V6, P9, DOI 10.1016/0141-5425(84)90003-7
[4]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[5]   VARIABILITY AND RELIABILITY OF THE PENDULUM TEST FOR SPASTICITY USING A CYBEX-II ISOKINETIC DYNAMOMETER [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (05) :659-661
[6]  
BOHANNON RW, 1990, ARCH PHYS MED REHAB, V71, P330
[7]   The Leg Drop Pendulum Test performed under general anesthesia in spastic cerebral palsy [J].
Fee, JW ;
Miller, F .
DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2004, 46 (04) :273-281
[8]  
FEINSTEIN AR, 1985, CLIN EPIDEMIOLOGY
[9]  
Fowler EG, 2000, DEV MED CHILD NEUROL, V42, P182
[10]   Muscle length effect on the pendulum test [J].
Fowler, V ;
Canning, CG ;
Carr, JH ;
Shepherd, RB .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (02) :169-171