Green light photoplethysmography monitoring of free flaps

被引:26
作者
Futran, ND
Stack, BC
Hollenbeak, C
Scharf, JE
机构
[1] Univ Washington, Sch Med, Dept Otolaryngol Head & Neck Surg, Seattle, WA 98195 USA
[2] St Louis Univ, Sch Med, Dept Otolaryngol Head & Neck Surg, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Otolaryngol Head & Neck Surg, Grad Hlth Adm Program, St Louis, MO 63110 USA
[4] Univ S Florida, Sch Med, Dept Anesthesiol, Tampa, FL 33620 USA
关键词
D O I
10.1001/archotol.126.5.659
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: Monitoring strategies have been developed to address the issue of detecting postoperative free nap ischemia in an effort to permit intervention and flap salvage. No one existing noninvasive method has been widely accepted in a clinical setting. Green light photoplethysmography (GLP) uses a diode to transmit green light into a tissue. Reflected light from hemoglobin in dermal capillary red blood cells is analyzed as light intensity along a frequency spectrum. A pure peak signal (1-2 Hz) is identified and provides a way to distinguish between perfused and nonperfused tissue. Design: Prospective, blinded comparison. Subjects: Sixty of 72 consecutive patients considered for free flap reconstruction were enrolled in a protocol to evaluate the efficacy of GLP. Intervention: After free flap elevation, but before pedicle ligation, 120-second baseline measurements were obtained; 120-second measurements then occurred 5 minutes after the onset or release of individual venous or arterial occlusion. Signals were processed by fast Fourier transfer; a mean alternating current-direct current (AC/ DC) ratio was cultivated for each signal. All data were analyzed in a blinded fashion. Results: The AC/DC ratio of GLP was statistically significant across all flap perfusion states (P<.001). Each condition resulted in a unique GLP signal within 5 minutes of manipulation of each vessel. Conclusions: Green light photoplethysmography with AC/DC ratio analysis provides a rapid, precise method with which to determine flap ischemia and can differentiate venous compromised and arterial compromised flaps almost immediately after the onset of an ischemic insult. It may provide a clinically useful tool for postoperative free flap monitoring.
引用
收藏
页码:659 / 662
页数:4
相关论文
共 17 条
[1]  
BIEMER E, 1981, INT SURG, V66, P37
[2]   Unsurpassed reliability of free flaps for head and neck reconstruction [J].
Blackwell, KE .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1999, 125 (03) :295-299
[3]   ESTABLISHMENT OF NORMAL RANGES OF LASER DOPPLER BLOOD-FLOW IN AUTOLOGOUS TISSUE-TRANSPLANTS [J].
CLINTON, MS ;
SEPKA, RS ;
BRISTOL, D ;
PEDERSON, WC ;
BARWICK, WJ ;
SERAFIN, D ;
KLITZMAN, B .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (02) :299-309
[4]   THE ROLE OF EMERGENT EXPLORATION IN FREE-TISSUE TRANSFER - A REVIEW OF 150 CONSECUTIVE CASES [J].
HIDALGO, DA ;
JONES, CS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (03) :492-498
[5]   Continuous tissue oxygen tension measurement as a monitor of free-flap viability [J].
Hirigoyen, MB ;
Blackwell, KE ;
Zhang, WX ;
Silver, L ;
Weinberg, H ;
Urken, ML .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (03) :763-773
[6]   Postoperative blood flow monitoring after free-tissue transfer by means of the hydrogen clearance technique [J].
Machens, HG ;
Mailaender, P ;
Reimer, R ;
Pallua, N ;
Lei, Y ;
Berger, A .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (02) :493-505
[7]   TECHNIQUES OF POSTOPERATIVE BLOOD-FLOW MONITORING AFTER FREE TISSUE TRANSFER - AN OVERVIEW [J].
MACHENS, HG ;
MAILAENDER, P ;
RIECK, B ;
BERGER, A .
MICROSURGERY, 1994, 15 (11) :778-786
[8]   NO-REFLOW PHENOMENON IN EXPERIMENTAL FREE FLAPS [J].
MAY, JW ;
CHAIT, LA ;
OBRIEN, BM ;
HURLEY, JV .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1978, 61 (02) :256-267
[9]  
OBERG PA, 1984, ACTA MED SCAND, P17
[10]   Signal processing methods for pulse oximetry [J].
Rusch, TL ;
Sankar, R ;
Scharf, JE .
COMPUTERS IN BIOLOGY AND MEDICINE, 1996, 26 (02) :143-159