A morphometric comparison of trabecular structure of human ilium between microcomputed tomography and conventional histomorphometry

被引:93
作者
Uchiyama, T
Tanizawa, T
Muramatsu, H
Endo, N
Takahashi, HE
Hara, T
机构
[1] NIIGATA UNIV,GRAD SCH SCI & TECHNOL,NIIGATA 95021,JAPAN
[2] NIIGATA UNIV,SCH ENGN,DEPT MECH ENGN,NIIGATA,JAPAN
关键词
D O I
10.1007/s002239900373
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recently, an imaging technique using micro-computed tomography (micro-CT) has emerged as a method for nondestructively assessing the microarchitecture of unprocessed surgical bone biopsy specimens. Using micro-CT, two-dimensional (2D) axial images were obtained from undecalcified transiliac bone biopsies which were taken from 15 patients with various metabolic bone diseases. Total area, bone area, and bone perimeter were determined, from which the bone volume (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular separation (Tb.Sp) were calculated semiautomatically and instantaneously. To evaluate the validity of this technique as a useful tool, the results were compared with those obtained from conventional histomorphometry. There were significant correlations between the two techniques for all parameters, with correlation coefficients ranging from 0.759 (Tb.N, P < 0.005) to 0.949 (BV/TV, P < 0.0001). Different resolutions seem to lead to major differences in perimeter values measured by the two methods. These factors may explain why the correlation coefficients of Tb.N and Tb.Th estimated from the perimeter and area is lower than that of BV/TV. Our results show that the micro-CT based on 2D images is a useful tool for imaging and nondestructively quantifying the microarchitecture of trabecular bone in unprocessed surgical bone specimens.
引用
收藏
页码:493 / 498
页数:6
相关论文
共 22 条
  • [1] CT IMAGE-ANALYSIS OF THE VERTEBRAL TRABECULAR NETWORK INVIVO
    CHEVALIER, F
    LAVALJEANTET, AM
    LAVALJEANTET, M
    BERGOT, C
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (01) : 8 - 13
  • [2] CHUNG HW, 1995, J BONE MINER RES, V10, P1452
  • [3] INTEROBSERVER AND INTRAOBSERVER VARIATION IN BONE HISTOMORPHOMETRY
    COMPSTON, JE
    VEDI, S
    STELLON, AJ
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1986, 38 (02) : 67 - 70
  • [4] *CONS DEV C, 1993, AM J MED, V94, P646
  • [5] COURPRON P, 1977, BONE HISTOMORPHOMETR, P39
  • [6] HIGH SPATIAL-RESOLUTION IMAGING OF BONE-MINERAL USING COMPUTED MICROTOMOGRAPHY - COMPARISON WITH MICRORADIOGRAPHY AND UNDECALCIFIED HISTOLOGIC SECTIONS
    ENGELKE, K
    GRAEFF, W
    MEISS, L
    HAHN, M
    DELLING, G
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (04) : 341 - 349
  • [7] Engelke K, 1996, J BONE MINER RES, V11, P480
  • [8] TETRACYCLINE-BASED HISTOLOGICAL ANALYSIS OF BONE REMODELING
    FROST, HM
    [J]. CALCIFIED TISSUE RESEARCH, 1969, 3 (03): : 211 - &
  • [9] Hipp JA, 1996, J BONE MINER RES, V11, P286
  • [10] KINNEY JH, 1995, J BONE MINER RES, V10, P264