Evaluation of cerebral arterial flow with transcranial Doppler ultrasound: Theoretical development and phantom studies

被引:30
作者
Hatab, MR [1 ]
Giller, CA [1 ]
Clarke, GD [1 ]
机构
[1] UNIV TEXAS,SW MED CTR,DEPT NEUROSURG,DALLAS,TX 75235
关键词
transcranial Doppler ultrasound; blood flow; signal processing; flow index; area index;
D O I
10.1016/S0301-5629(97)00030-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Blood Bow information available from transcranial Doppler ultrasound is usually derived from velocity alone because no knowledge of vessel caliber is available, In cases such as vasospasm, where vessel size changes, the inference of flow from velocity becomes questionable. A computational technique was used to calculate a flow index and 2 vessel area indices based on the first and zero moments of the Doppler power spectrum, These indices were tested in a steady and pulsatile Bow phantom using 6 different diameter elastic tubes, Changes in the flow index showed good agreement with changes in timed volume flow for different flow rates, The vessel caliber indices correctly predicted changes in area when different diameter tubes were examined, These indices may prove useful in clinical settings where the constancy of Bow or vessel diameter between studies are in question, (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 35 条
[1]  
AASLID R, 1994, STROKE, V25, P1297
[2]   ASSESSMENT OF CEREBRAL AUTOREGULATION DYNAMICS FROM SIMULTANEOUS ARTERIAL AND VENOUS TRANSCRANIAL DOPPLER RECORDINGS IN HUMANS [J].
AASLID, R ;
NEWELL, DW ;
STOOSS, R ;
SORTEBERG, W ;
LINDEGAARD, KF .
STROKE, 1991, 22 (09) :1148-1154
[3]   VISUALLY EVOKED DYNAMIC BLOOD-FLOW RESPONSE OF THE HUMAN CEREBRAL-CIRCULATION [J].
AASLID, R .
STROKE, 1987, 18 (04) :771-775
[4]   CEREBRAL AUTO-REGULATION DYNAMICS IN HUMANS [J].
AASLID, R ;
LINDEGAARD, KF ;
SORTEBERG, W ;
NORNES, H .
STROKE, 1989, 20 (01) :45-52
[5]   INSTANTANEOUS MEASUREMENT OF BLOODFLOW BY ULTRASONIC MEANS [J].
ARTS, MGJ ;
ROEVROS, JMJ .
MEDICAL & BIOLOGICAL ENGINEERING, 1972, 10 (01) :23-&
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   PERFORMANCE TESTS OF DOPPLER ULTRASOUND EQUIPMENT WITH A TISSUE AND BLOOD-MIMICKING PHANTOM [J].
BOOTE, EJ ;
ZAGZEBSKI, JA .
JOURNAL OF ULTRASOUND IN MEDICINE, 1988, 7 (03) :137-147
[8]   TRANSCRANIAL DOPPLER MEASUREMENTS OF THE MIDDLE CEREBRAL-ARTERY - EFFECT OF HEMATOCRIT [J].
BRASS, LM ;
PAVLAKIS, SG ;
DEVIVO, D ;
PIOMELLI, S ;
MOHR, JP .
STROKE, 1988, 19 (12) :1466-1469
[9]   TRANSCRANIAL DOPPLER ULTRASOUND - PRESENT STATUS [J].
CAPLAN, LR ;
BRASS, LM ;
DEWITT, LD ;
ADAMS, RJ ;
GOMEZ, C ;
OTIS, S ;
WESCHLER, LR ;
VONREUTERN, GM .
NEUROLOGY, 1990, 40 (04) :696-700
[10]   INFLUENCE OF BEAM PROFILE AND DEGREE OF INSONATION ON THE CW DOPPLER ULTRASOUND SPECTRUM AND MEAN VELOCITY [J].
COBBOLD, RSC ;
VELTINK, PH ;
JOHNSTON, KW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (06) :364-370