Peripheral nerve morphometry: Comparison between manual and semi-automated methods in the analysis of a small nerve

被引:40
作者
Demetrio da Silva, Andre Pelegrino
Rodrigues Jordao, Caroline Echavarria
Sassoli Fazan, Valeria Paula
机构
[1] Univ Sao Paulo, Sch Med Ribeirao Preto, Dept Surg & Anat, BR-14049900 Ribeirao Preto, Brazil
[2] Univ Sao Paulo, Sch Med Ribeirao Preto, Dept Neurol, BR-14049900 Ribeirao Preto, Brazil
基金
巴西圣保罗研究基金会;
关键词
manual morphometry; semi-automated morphometry; peripheral nerves; light microscopy;
D O I
10.1016/j.jneumeth.2006.06.012
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Manual nerve morphometry has been usually described as tedious, time consuming, difficult to perform correctly and subject to many sources of errors. The above considerations might suggest that fully automated image analysis systems could be ideally programmed to analyze myelinated fibers. However, operator intervention is necessary to manually eliminate dark tissue elements such as pericytes and Schwann cell nuclei. The aims of the present study were to compare the manual and semi-automated techniques in the evaluation of a small nerve, comparing the most commonly used morphometric parameters for nerve descriptions. The aortic depressor nerves (ADN) of male Wistar rats (N = 12) were prepared with conventional techniques for epoxy resin embedding. Manual morphometry was performed on photomicrographs using a digitizing tablet. Semi-automated morphometry was performed with the aid of computer software, on the same negative images used on the photographic procedure, which were scanned and digitized to a microcomputer. Our results show no differences between data obtained with both methods, for any of the evaluated parameters (area, perimeter, diameters, myelin sheath thickness, g ratio, distribution histograms). In conclusion, manual morphometry reproduced data obtained with semi-automated technique in a small nerve, with the advantages of being less-expensive and an affordable method. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 29 条
[1]
AUTOMATED NERVE-FIBER SIZE AND MYELIN SHEATH MEASUREMENT USING MICROCOMPUTER-BASED DIGITAL IMAGE-ANALYSIS - THEORY, METHOD AND RESULTS [J].
AUER, RN .
JOURNAL OF NEUROSCIENCE METHODS, 1994, 51 (02) :229-238
[2]
MORPHOMETRIC ANALYSIS OF EXPERIMENTAL SPINAL-CORD INJURY IN THE CAT - THE RELATION OF INJURY INTENSITY TO SURVIVAL OF MYELINATED AXONS [J].
BLIGHT, AR ;
DECRESCITO, V .
NEUROSCIENCE, 1986, 19 (01) :321-+
[3]
QUANTITATIVE-ANALYSIS OF MICROGRAPHS BY COMPUTER GRAPHICS [J].
DUNN, RF ;
OLEARY, DP ;
KUMLEY, WE .
JOURNAL OF MICROSCOPY, 1975, 105 (NOV) :205-213
[4]
AUTOMATED MEASUREMENT OF PERIPHERAL-NERVE FIBERS IN TRANSVERSE SECTION [J].
ELLIS, TJ ;
ROSEN, D ;
CAVANAGH, JB .
JOURNAL OF BIOMEDICAL ENGINEERING, 1980, 2 (04) :272-280
[5]
NERVE-FIBER MORPHOMETRY - A COMPARISON OF TECHNIQUES [J].
EWART, DP ;
KUZON, WM ;
FISH, JS ;
MCKEE, NH .
JOURNAL OF NEUROSCIENCE METHODS, 1989, 29 (02) :143-150
[6]
Aortic depressor nerve myelinated fibers in acute and chronic experimental diabetes [J].
Fazan, VPS ;
Salgado, HC ;
Barreira, AA .
AMERICAN JOURNAL OF HYPERTENSION, 2006, 19 (02) :153-160
[7]
Relation between myelin area and axon diameter in the aortic depressor nerve of spontaneously hypertensive rats [J].
Fazan, VPS ;
Salgado, HC ;
dos Reis, GC ;
Barreira, AA .
JOURNAL OF NEUROSCIENCE METHODS, 2005, 148 (02) :130-136
[8]
A descriptive and quantitative light and electron microscopy study of the aortic depressor nerve in normotensive rats [J].
Fazan, VPS ;
Salgado, HC ;
Barreira, AA .
HYPERTENSION, 1997, 30 (03) :693-698
[9]
Morphology of aortic depressor nerve myelinated fibers in normotensive Wistar-Kyoto and spontaneously hypertensive rats [J].
Fazan, VPS ;
Fazan, R ;
Salgado, HC ;
Barreira, AA .
JOURNAL OF THE AUTONOMIC NERVOUS SYSTEM, 1999, 77 (2-3) :133-139
[10]
Aortic depressor nerve unmyelinated fibers in spontaneously hypertensive rats [J].
Fazan, VPS ;
Salgado, HC ;
Barreira, AA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (04) :H1560-H1564