A direct comparison of wet, dry and insulating bioelectric recording electrodes

被引:534
作者
Searle, A [1 ]
Kirkup, L [1 ]
机构
[1] Univ Technol Sydney, Dept Appl Phys, Sydney, NSW 2007, Australia
关键词
electrodes; dry; insulating; artefact; impedance; noise; interference;
D O I
10.1088/0967-3334/21/2/307
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Alternatives to conventional wet electrode types are keenly sought for biomedical use and physiological research, especially when prolonged recording of biosignals is demanded. This paper describes a quantitative comparison of three types of bioelectrode (wet, dry and insulating) based on tests involving electrode impedance, static interference and motion artefact induced by various means. Data were collected simultaneously, and in the same physical environment for all electrode types. Results indicate that in many situations the performance of dry and insulating ng electrodes compares favourably with wet electrodes. The influence of non-stationary electric fields on shielded dry and insulating electrode types was compared to wet types. It was observed that interference experienced by dry and insulating electrode types was 40 dB and 34 dB less than that experienced by wet electrode types. Similarly, the effect of motion artefact on dry and insulating electrodes was compared to wet types. Artefact levels for dry and insulating electrodes were significantly higher than those for wet types at the beginning of trials conducted. By the end of the trial periods artefact levels for dry and insulating types were lower than wet electrodes by an average of 8.2 dB and 6.8 dB respectively. The reservations expressed in other studies regarding the viability of dry and insulating electrodes for reliable sensing of biosignals are not supported by the work described here.
引用
收藏
页码:271 / 283
页数:13
相关论文
共 42 条
[1]  
ADLI, 1998, C REC IEEE INSTR MEA, V1, P235
[2]   ELECTROCARDIOGRAM RECORDING WITH PASTELESS ELECTRODES [J].
BERGEY, GE ;
SQUIRES, RD ;
SIPPLE, WC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1971, BM18 (03) :206-&
[3]   CONTACT-DERMATITIS CAUSED BY ECG ELECTRODE PASTE [J].
COCHRAN, RJ ;
ROSEN, T .
SOUTHERN MEDICAL JOURNAL, 1980, 73 (12) :1667-1668
[4]   CONTACT-DERMATITIS CAUSED BY ECG ELECTRODE JELLY [J].
COSKEY, RJ .
ARCHIVES OF DERMATOLOGY, 1977, 113 (06) :839-840
[5]   INSULATED ELECTROCARDIOGRAM ELECTRODES [J].
DAVID, RM ;
PORTNOY, WM .
MEDICAL & BIOLOGICAL ENGINEERING, 1972, 10 (06) :742-751
[6]   PASTELESS ELECTRODE FOR CLINICAL USE [J].
DE LUCA, CJ ;
LEFEVER, RS ;
STULEN, FB .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (03) :387-390
[7]   The origin of skin-stretch-caused motion artifacts under electrodes [J].
deTalhouet, H ;
Webster, JG .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 (02) :81-93
[8]   ALLERGIC CONTACT-DERMATITIS FROM TENS GEL [J].
DWYER, CM ;
CHAPMAN, RS ;
FORSYTH, A .
CONTACT DERMATITIS, 1994, 30 (05) :305-305
[9]  
Elliott Wallace R., 1995, Biomedical Instrumentation and Technology, V29, P495
[10]  
FERNANDEZ M, 1996, ANN INT C IEEE ENG M, V1, P97