Analysis of corticosteroids in biofluids by capillary electrochromatography with gradient elution

被引:67
作者
Taylor, MR
Teale, P
Westwood, SA
Perrett, D
机构
[1] UNIV LONDON ST BARTHOLOMEWS HOSP MED COLL,LONDON EC1A 7BE,ENGLAND
[2] ROYAL LONDON SCH MED & DENT,LONDON EC1A 7BE,ENGLAND
关键词
D O I
10.1021/ac970005n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrochromatography (CEC) with gradient elution was used to separate mixtures of corticosteroids (adrenosterone, hydrocortisone, dexamethasone, fluocortolone) in extracts of equine urine and plasma, Urine samples were first purified using solid phase extraction, Two purification steps were necessary to prevent contamination of the CEC column, Plasma was purified using automated dialysis, A laboratory-built CEC interface, connected to a gradient HPLC system, delivered samples and mobile phase to the CEC column, CEC was performed in fused-silica capillaries of 50 mu m i.d., 24 cm total length, and 16 cm effective length packed with Apex ODS, 3 mu m particle size, The mobile phase was ammonium acetate (5 mM) in water/acetonitrile. Acetonitrile in the mobile phase was varied from 9 to 80% (v/v) using the gradient HPLC system, Detection was by UV absorbance at 240 nm, Samples, 10-250 mu L, were injected into the mobile phase stream and loaded onto the CEC column under an applied field of 1.04 kV cm(-1) and a CEC column head pressure of 12 bar, Mobile phase flow rate through the sampling interface was 100 mu L min(-1), The system was reproducible and could be left in unattended operation for long periods, After injection of 200 urine extracts, a broadening of peaks was observed but the CEC column was still serviceable.
引用
收藏
页码:2554 / 2558
页数:5
相关论文
共 13 条
[1]  
BAYER E, 1996, Patent No. 4447333
[2]   PRESSURIZED GRADIENT ELECTRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEHNKE, B ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :93-98
[3]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[4]  
*BRIT JOCK CLUB, 1996, ORD BRIT HORS BOARD, P350
[5]   PRESSURIZED FLOW ELECTROCHROMATOGRAPHY WITH REVERSED-PHASE CAPILLARY COLUMNS [J].
EIMER, T ;
UNGER, KK ;
TSUDA, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :649-653
[6]  
Houghton E., 1988, Proceedings of the 7th International Conference of Racing Analysts and Veterinarians, Louisville, Kentucky, April 12-15, 1988.., P507
[7]   ELECTROCHROMATOGRAPHY IN PACKED TUBES USING 1.5 TO 50 MU-M SILICA-GELS AND ODS BONDED SILICA-GELS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1991, 32 (7-8) :317-328
[8]  
ROSS G, 1996, INT LAB, V26, pA10
[9]  
SAMUELS T, 1994, P 10 INT C RAC AN VE, P115
[10]   CAPILLARY ELECTROCHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY - A MICROANALYSIS TECHNIQUE [J].
SCHMEER, K ;
BEHNKE, B ;
BAYER, E .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3656-3658