Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation

被引:40
作者
Azadani, Ali N.
Jaussaud, Nicolas
Matthews, Peter B.
Ge, Liang
Guy, T. Sloane
Chuter, Timothy A. M.
Tseng, Elaine E. [1 ]
机构
[1] Univ Calif San Francisco, Med Ctr, Div Cardiothorac Surg, Dept Surg, San Francisco, CA 94143 USA
关键词
HEART-VALVE; HEMODYNAMIC PERFORMANCE; MITRAL REGURGITATION; STENOSIS; FEASIBILITY; REPLACEMENT; EXPERIENCE; PROSTHESIS;
D O I
10.1016/j.athoracsur.2009.08.025
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background. Mild to moderate paravalvular leaks commonly occur after transcatheter aortic valve (TAV) implantation. Current TAVs match and may exceed hemodynamic performance of surgically implanted bioprostheses based on pressure gradient and effective orifice area. However, these hemodynamic criteria do not account for paravalvular leaks. We recently demonstrated that TAV implantation within 23 mm Perimount bioprostheses (Edwards Lifesciences, Irvine, CA) yields similar hemodynamics to the 23 mm Perimount valve. However, mild paravalvular leakage was seen after TAV implantation. The present study quantifies energy loss during the entire cardiac cycle to assess the impact of TAV paravalvular leaks on the ventricle. Methods. Four TAVs designed to mimic the 23 mm SAPIEN valve (Edwards Lifesciences) were created. Transvalvular energy loss of 19, 21, and 23 mm Carpentier-Edwards bioprostheses were obtained in vitro within a pulse duplicator as a hemodynamic baseline (n = 4). The 23 mm TAVs were subsequently implanted within the 23 mm bioprostheses to assess energy loss due to paravalvular leak. Results. The 23 mm bioprosthesis demonstrated the least energy loss (213.25 +/- 31.35 mJ) compared with the 19 mm (330.00 +/- 36.97 mJ, p = 0.003) and 21 mm bioprostheses (298.00 +/- 37.25 mJ, p = 0.008). The TAV controls had similar energy loss (241.00 +/- 30.55 mJ, p = 0.17) as the 23 mm bioprostheses. However, after TAV implantation, total energy loss increased to 365.33 +/- 8.02 mJ significantly exceeding the energy loss of the 23 mm bioprosthesis (p < 0.001). Due to mild TAV paravalvular leakage, 39% of energy loss occurred during diastole. Conclusions. Substantial energy loss during diastole occurs due to TAV paravalvular leakage. In the presence of mild paravalvular leakage, TAV implantation imposes a significantly higher workload on the left ventricle than an equivalently sized surgically implanted bioprosthesis.
引用
收藏
页码:1857 / 1863
页数:7
相关论文
共 31 条
[1]
Energy loss for evaluating heart valve performance [J].
Akins, Cary W. ;
Travis, Brandon ;
Yoganathan, Ajit P. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (04) :820-833
[2]
[Anonymous], 2005, 58402005 ISO
[3]
Azadani AN, 2009, J HEART VALVE DIS, V18, P367
[4]
Clinical efficacy of Doppler-echocardiographic indices of aortic valve stenosis:: A comparative test-based analysis of outcome [J].
Bermejo, J ;
Odreman, R ;
Feijoo, J ;
Moreno, MM ;
Gómez-Moreno, P ;
García-Fernández, MA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (01) :142-151
[5]
Surgery insight: percutaneous treatment of prosthetic paravalvular leaks [J].
Bhindi, Ravinay ;
Bull, Sacha ;
Schrale, Ryan G. ;
Wilson, Neil ;
Ormerod, Oliver J. .
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (03) :140-147
[6]
Percutaneous transcatheter aortic valve implantation: Evolution of the technology [J].
Chiam, Paul T. L. ;
Ruiz, Carlos E. .
AMERICAN HEART JOURNAL, 2009, 157 (02) :229-242
[7]
Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[8]
Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[9]
Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[10]
Division of Cardiovascular and Neurological Devices, 1994, DRAFT REPL HEART VAL, P1