Technical and physiological background of plasma volume measurement with indocyanine green: a clarification of misunderstandings

被引:52
作者
Jacob, Matthias
Conzen, Peter
Finsterer, Udilo
Krafft, Alexander
Becker, Bernhard F.
Rehm, Markus
机构
[1] Univ Munich, Anasthesiol Klin, D-80336 Munich, Germany
[2] Univ Munich, Inst Physiol, D-8000 Munich, Germany
[3] Univ Spital Zurich, Klin Geburtshilfe, Zurich, Switzerland
关键词
distribution space; plasma protein; endothelial glycocalyx; endothelial surface layer; albumin;
D O I
10.1152/japplphysiol.00740.2006
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The indocyanine green ( ICG) dilution technique ( DT) is frequently used for plasma volume ( PV) measurement. However, because of inadequate knowledge about the properties of this dye, lack of accuracy has been attributed to the method. The aim of this report is to provide physiological background information about the ICG- DT to avoid some profound misunderstandings. When performing tracer dilution, one has to consider the tracer's distribution space before interpreting the result. For ICG, the distribution space is the total PV, i. e., circulating + noncirculating PV, fixed within the endothelial glycocalyx. The distribution space of red blood cells and large molecules, in contrast, is only the circulating part of PV. Therefore, it is erroneous to compare directly PV derived from different tracer dilution methods. The transcapillary escape rate of ICG should not relevantly influence measured PV if the method is performed properly, i. e., if a short time window of measurement is subjected to monoexponential extrapolation. A major problem of PV measurement in general is that the target itself is very inconstant. Thus, checking for constancy of ICG- DT with two consecutive measurements is unreliable. Nevertheless, the ICG- DT is a useful tool for determining PV, provided it is well understood by the investigator to enable correct interpretation of the results.
引用
收藏
页码:1235 / 1242
页数:8
相关论文
共 55 条
[1]   MICROSPHERE AND DILUTION TECHNIQUES FOR THE DETERMINATION OF BLOOD FLOWS AND VOLUMES IN CONSCIOUS MICE [J].
BARBEE, RW ;
PERRY, BD ;
RE, RN ;
MURGO, JP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (03) :R728-R733
[2]   INTRAVITAL DETECTION OF SKIN CAPILLARY ANEURYSMS BY VIDEOMICROSCOPY WITH INDOCYANINE GREEN IN PATIENTS WITH PROGRESSIVE SYSTEMIC-SCLEROSIS AND RELATED DISORDERS [J].
BOLLINGER, A ;
SAESSELI, B ;
HOFFMANN, U ;
FRANZECK, UK .
CIRCULATION, 1991, 83 (02) :546-551
[3]   DETERMINATION OF BLOOD VOLUME USING INDOCYANINE GREEN (CARDIO-GREENR) DYE [J].
BRADLEY, EC ;
BARR, JW .
LIFE SCIENCES PART 1 PHYSIOLOGY AND PHARMACOLOGY AND PART 2 BIOCHEMISTRY GENERAL AND MOLECULAR BIOLOGY, 1968, 7 (17P1) :1001-&
[4]  
BRULISAUER M, 1991, INT J MICROCIRC, V10, P21
[5]  
BUSSE MW, 1993, ANAESTHESIA, V48, P41
[6]  
CAESAR J, 1961, CLIN SCI, V21, P43
[7]   INDOCYANINE GREEN - OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION [J].
CHERRICK, GR ;
STEIN, SW ;
LEEVY, CM ;
DAVIDSON, CS .
JOURNAL OF CLINICAL INVESTIGATION, 1960, 39 (04) :592-600
[8]   Blood volume studies III. Behavior of large series of dyes introduced into the circulating blood [J].
Dawson, AB ;
Evans, HM ;
Whipple, GH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1920, 51 (02) :232-256
[9]  
FLECK A, 1985, LANCET, V1, P781
[10]  
FOX IJ, 1957, P STAFF M MAYO CLIN, V32, P478