Technique failure in peritoneal dialysis and its impact on patient survival

被引:9
作者
Woodrow, G
Turney, JH
Brownjohn, AM
机构
来源
PERITONEAL DIALYSIS INTERNATIONAL | 1997年 / 17卷 / 04期
关键词
peritonitis; CAPD technique survival; mortality;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the frequency and causes of continuous ambulatory peritoneal dialysis (CARD) technique failure and its effect on patient outcome. Design: Retrospective study of CAPD technique and patient outcome. Setting: Teaching hospital renal unit. Patients: All 221 patients commencing CAPD over a 14-year period. Outcome measures: Outcomes assessed included patient survival and technique survival (with change to hemodialysis being considered as technique failure). Results: CAPD failure occurred in 46 patients, with a CAPD technique survival of 93%, 73%, and 63% at 1, 3, and 5 years after start of treatment. Peritonitis was the major cause of technique failure. CAPD system had no effect on technique survival, despite the lower peritonitis rate in patients using Y-connection systems. Overall patient survival was 91%, 72%, and 53% at 1, 3, and 5 years after start of treatment, with increasing age and diabetes being associated with a worse outcome. There was a high early mortality after CAPD failure, with an actuarial survival of only 61% 1 year later. Conclusion: Failure of CAPD is an important problem, with peritonitis being the major cause, either directly, or indirectly by the later effects of damage to the peritoneal membrane with loss of dialysis adequacy. The high mortality in the period following CAPD failure warrants careful monitoring of patients during this phase, along with efforts to optimize correctable factors such as nutrition, adequacy of the new form of dialysis, and treatment of residual sepsis.
引用
收藏
页码:360 / 364
页数:5
相关论文
共 14 条
[1]  
ATAMAN R, 1988, CLIN NEPHROL, V30, pS71
[2]  
Churchill DN, 1996, J AM SOC NEPHROL, V7, P198
[3]  
CHURCHILL DN, 1989, PERITON DIALYSIS INT, V9, P159
[4]   THE INFLUENCE OF CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS CONNECTION TECHNIQUE ON PERITONITIS RATE AND TECHNIQUE SURVIVAL [J].
DOMRONGKITCHAIPORN, S ;
KARIM, M ;
WATSON, L ;
MORIARTY, M .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (01) :50-58
[5]  
GEERLINGS W, 1994, NEPHROL DIAL TRANSPL, V9, P6
[6]  
KIM D, 1984, T AM SOC ART INT ORG, V30, P494
[7]  
MAIORCA R, 1983, LANCET, V2, P642
[8]   EFFECT OF CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS ON A BRITISH RENAL UNIT [J].
MORGAN, AG ;
BURDEN, RP .
BRITISH MEDICAL JOURNAL, 1986, 293 (6552) :935-937
[9]   MORBIDITY AND MORTALITY OF CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS - REGIONAL EXPERIENCE AND LONG-TERM PROSPECTS [J].
NISSENSON, AR ;
GENTILE, DE ;
SODERBLOM, RE ;
OLIVER, DF ;
BRAX, C .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1986, 7 (03) :229-234
[10]  
POPOVICH RP, 1976, ABSTR AM SOC ART INT, V5, P64