A preliminary study of a microconcentric nebulizer (MCN) as the sample introduction device for the capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS) system for mercury speciation application is described. Samples containing ionic mercury compounds were subjected to electrophoretic separation before injection into the microconcentric nebulizer. The species studied include inorganic mercury (Hg(II)), methyl mercury (CH3-Hg) and ethyl mercury (C2H5-Hg). The sensitivity, detection limit and repeatability of the CE-ICP-MS system with a microconcentric nebulizer were comparable to CE-ICP-MS system with other nebulization techniques of various metal speciation studies. Reproducibility of peak height and migration time was better than 3 and 2%, respectively. The limits of detection for various mercury species were in the range of 0.08-0.17 mu g ml(-1) Hg based on peak height. We determined the concentrations of mercury compound in contact lenses solutions purchased from the local market. The precision between sample replicates was better than 7% with CE-MCN-ICP-MS method. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:197 / 205
页数:9
相关论文
共 27 条
[1]   SPECIATION OF INORGANIC MERCURY(II) AND METHYLMERCURY BY VESICLE-MEDIATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COUPLED TO COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
AIZPUN, B ;
FERNANDEZ, ML ;
BLANCO, E ;
SANZMEDEL, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1279-1284
[2]   Determination of mercury species in sea-water by liquid chromatography with inductively coupled plasma mass spectrometric detection [J].
Bloxham, MJ ;
Gachanja, A ;
Hill, SJ ;
Worsfold, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (02) :145-148
[3]   SPECIATION OF MERCURY IN HUMAN WHOLE-BLOOD BY CAPILLARY GAS-CHROMATOGRAPHY WITH A MICROWAVE-INDUCED PLASMA EMISSION DETECTOR SYSTEM FOLLOWING COMPLEXOMETRIC EXTRACTION AND BUTYLATION [J].
BULSKA, E ;
EMTEBORG, H ;
BAXTER, DC ;
FRECH, W ;
ELLINGSEN, D ;
THOMASSEN, Y .
ANALYST, 1992, 117 (03) :657-663
[5]   DETERMINATION OF THIMEROSAL IN BIOLOGICAL PRODUCTS BY LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION [J].
BUSHEE, DS ;
MOODY, JR ;
MAY, JC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) :773-775
[6]   DIRECT COUPLING OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY TO MICROWAVE-INDUCED PLASMA-ATOMIC EMISSION-SPECTROMETRY VIA VOLATILE-SPECIES GENERATION AND ITS APPLICATION TO MERCURY AND ARSENIC SPECIATION [J].
COSTAFERNANDEZ, JM ;
LUNZER, F ;
PEREIROGARCIA, R ;
SANZMEDEL, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (11) :1019-1025
[7]   DETERMINATION OF MERCURY(II) AND ORGANOMERCURY COMPOUNDS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY WITH REDUCTIVE ELECTROCHEMICAL DETECTION [J].
EVANS, O ;
MCKEE, GD .
ANALYST, 1988, 113 (02) :243-246
[8]  
Foret F., 1993, CAPILLARY ZONE ELECT
[9]   CONTINUOUS-FLOW REDUCING VESSEL IN DETERMINATION OF MERCURIC COMPOUNDS BY LIQUID-CHROMATOGRAPHY COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
FUJITA, M ;
TAKABATAKE, E .
ANALYTICAL CHEMISTRY, 1983, 55 (03) :454-457
[10]   Capillary electrophoresis determination of methylmercury in fish and crab meat after extraction as the dithizone sulphonate complex [J].
Hardy, S ;
Jones, P .