Accuracy of serial screening for abdominal aortic aneurysms by ultrasound

被引:54
作者
Wilmink, ABM
Forshaw, M
Quick, CRG
Hubbard, CS
Day, NE
机构
[1] Birmingham Heartlands Hosp, Res Inst, Birmingham B9 5SS, W Midlands, England
[2] Univ Cambridge, Dept Epidemiol & Biostat, Cambridge, England
[3] Hinchingbrooke Hosp, Dept Radiol, Huntingdon, England
[4] Hinchingbrooke Hosp, Dept Surg, Huntingdon, England
[5] Medway Hosp, Gillingham, England
关键词
D O I
10.1136/jms.9.3.125
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: To assess the accuracy of screening for abdominal aortic aneurysms (AAAs) by ultrasound (US). Setting: An aneurysm screening programme in Huntingdon. Methods: False negative tests were identified by tracing all patients with a ruptured aneurysm who. were screened and then finding the number classified as normal on US. False positive tests were identified by calculating the number of aneurysmal aortas on US that were classified as normal on CT. Measurement variability of the infrarenal aortic diameter between US and CT was estimated. Results: 14 out of 93 patients with a ruptured AAA since 1991 had been screened. No ruptured aneurysm had been classified as normal on US. All 64 patients with an AAA larger than 4.5 cm on US had their aneurysm confirmed on CT. The mean difference between CT and US measurements was 4 mm. The limit of variability between CT and US was 12 mm. Conclusion: No false negative scans were found using a cut off point of 3 cm as abnormal. No false positives were found if subjects with an AAA exceeding 4.5 cm were referred for further procedures. A serial US screening policy has excellent screening performance, justifying its use as a screening tool.
引用
收藏
页码:125 / 127
页数:3
相关论文
共 10 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Clayton D., 1993, STAT MODELS EPIDEMIO
[3]   LIMITATIONS OF ULTRASONOGRAPHY IN SURVEILLANCE OF SMALL ABDOMINAL AORTIC-ANEURYSMS [J].
ELLIS, M ;
POWELL, JT ;
GREENHALGH, RM .
BRITISH JOURNAL OF SURGERY, 1991, 78 (05) :614-616
[4]   ULTRASONOGRAPHY AND CT SCANNING - COMPARATIVE-STUDY OF ABDOMINAL AORTIC-ANEURYSMS [J].
GOMES, MN ;
HAKKAL, HG ;
SCHELLINGER, D .
COMPUTERIZED TOMOGRAPHY, 1978, 2 (02) :99-110
[5]   DISCORDANCE IN THE SIZING OF ABDOMINAL AORTIC-ANEURYSM AND ITS SIGNIFICANCE [J].
GRAEVE, AH ;
CARPENTER, CM ;
WICKS, JD ;
EDWARDS, WS .
AMERICAN JOURNAL OF SURGERY, 1982, 144 (06) :627-634
[6]   VARIABILITY IN MEASUREMENT OF ABDOMINAL AORTIC-ANEURYSMS [J].
LEDERLE, FA ;
WILSON, SE ;
JOHNSON, GR ;
REINKE, DB ;
LITTOOY, FN ;
ACHER, CW ;
MESSINA, LM ;
BALLARD, DJ ;
ANSEL, HJ .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) :945-952
[7]  
Thomas P R, 1994, J Med Screen, V1, P3
[8]  
Wilmink A B, 1997, J Med Screen, V4, P49
[9]   The incidence of small abdominal aortic aneurysms and the change in normal infrarenal aortic diameter: Implications for screening [J].
Wilmink, ABM ;
Hubbard, CS ;
Day, NE ;
Quick, CRG .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 21 (02) :165-170
[10]   The influence of screening on the incidence of ruptured abdominal aortic aneurysms [J].
Wilmink, TBM ;
Quick, CRG ;
Hubbard, CS ;
Day, NE .
JOURNAL OF VASCULAR SURGERY, 1999, 30 (02) :203-208