In vitro and in vivo performance of Ti6A14V implants with plasma-sprayed osteoconductive hydroxylapatite bioinert titania bond coat "duplex" systems:: an experimental study in sheep

被引:37
作者
Heimann, RB [1 ]
Schürmann, N
Müller, RT
机构
[1] Tech Univ Bergakad Freiberg, Dept Mineral, D-09596 Freiberg, Germany
[2] Univ Hosp Essen, Clin & Polyclin Orthopaed, D-45122 Essen, Germany
关键词
D O I
10.1023/B:JMSM.0000042691.74922.1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
To evaluate the in vivo performance of "duplex" hydroxylapatite top coat/TiO2 bond coat systems, cylindrical Ti6Al4V rods of 130 mm in length and 11-13 mm in diameter were coated by atmospheric plasma spray (APS) technique with both a standard hydroxylapatite (HAp) layer and a HAp+TiO2 bond coat "duplex" layer. In this pilot study coated and uncoated rods serving as controls were implanted into the femur of sheep so that their distal ends were freely suspended in the medulla of the femur. After an observation time of six months it was found that bone apposition and bone ingrowth were considerably increased in the presence of a osteoconductive coating. In particular, in vivo spalling and delamination frequently observed with HAp coatings was virtually absent in duplex coatings owing to the strong adhesion of the bond coat to the HAp top coat that anchored the latter solidly to the metallic surface of the implant. Some tentative mechanisms leading to this improved coating adhesion will be discussed. (C) 2004 Kluwer Academic Publishers.
引用
收藏
页码:1045 / 1052
页数:8
相关论文
共 43 条
[1]
CAULIER H, 1995, MAT CLIN APPL, P477
[3]
PLASMA SPRAYED COATINGS OF HYDROXYLAPATITE [J].
DEGROOT, K ;
GEESINK, R ;
KLEIN, CPAT ;
SEREKIAN, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (12) :1375-1381
[4]
Radiological and survival comparison of four methods of fixation of a proximal femoral stem [J].
Donnelly, WJ ;
Kobayashi, A ;
Freeman, MAR ;
Chin, TW ;
Yeo, H ;
West, M ;
Scott, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03) :351-360
[5]
DOPNER S, 2000, COMMUNICATION
[6]
Dissolution behavior of plasma-sprayed hydroxyapatite coatings [J].
Fazan, F ;
Marquis, PM .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (12) :787-792
[7]
CHARACTERIZATION OF THE INTERFACE IN THE PLASMA-SPRAYED HA COATING/TI-6AL-4V IMPLANT SYSTEM [J].
FILIAGGI, MJ ;
COOMBS, NA ;
PILLIAR, RM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (10) :1211-1229
[8]
Titanium release from dental implants: an in vivo study on sheep [J].
Finet, B ;
Weber, G ;
Cloots, R .
MATERIALS LETTERS, 2000, 43 (04) :159-165
[9]
GOTZE J, 2001, BIOMATERIALIEN, V2, P54, DOI DOI 10.1515/BIOMAT.2001.2.1.54
[10]
Grassmann O, 2000, J BIOMED MATER RES, V53, P685, DOI 10.1002/1097-4636(2000)53:6<685::AID-JBM11>3.0.CO