Stacking and quantitative analysis of lovastatin in urine samples by the transient moving chemical reaction boundary method in capillary electrophoresis

被引:28
作者
Li, Min
Fan, Liu-Yin
Zhang, Wei
Cao, Cheng-Xi
机构
[1] Shanghai Jiao Tong Univ, Sch Life Sci & Biotechnol, Lab Analyt Biochem & Bioseparat, Shanghai 200240, Peoples R China
[2] Chuzhou Univ, Dept Chem & Life Sci, Analyt Chem Lab, Chuzhou 239012, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary zone electrophoresis; stacking; lovastatin; moving chemical reaction boundary; urine;
D O I
10.1007/s00216-007-1169-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, sensitive, and useful concentration method for lovastatin (Lvt) in urine has been developed based on the transient moving chemical reaction boundary method (tMCRBM) in capillary electrophoresis. The MCRB is formed with acidic sample buffer (Gly-HCl) and alkaline running buffer (Gly-NaOH). The following optimal conditions were determined for stacking and separation: electrophoretic buffer of 100 mM Gly- NaOH (pH 11.52), sample buffer of 20 mM Gly-HCl (pH 4.93), fused-silica capillary of 76 cm x 75-mu m i.d (67 cm from detector), sample injection at 14 mbar for 3 min. A 21- to 26-fold increase in peak height was achieved for detection of Lvt in urine under the optimal conditions compared with normal capillary zone electrophoresis. By combining the sample pretreatment procedure with the stacking method, the sensitivity of Lvt in urine was increased by 105- to 130-fold. The limits of detection (LOD) and quantification (LOQ) for Lvt in urine were decreased to 8.8 ng/mL and 29.2 ng/mL, respectively. The intra-day and inter-day precision values (expressed as RSD) were 2.23-3.61% and 4.03-5.05%, respectively. The recoveries of the analyte at three concentration levels changed from 82.65 to 100.49%.
引用
收藏
页码:2719 / 2725
页数:7
相关论文
共 34 条
[1]  
ALBLERTS AW, 1980, J P NATL ACAD SCI US, V77, P3957
[2]   Investigation of the mechanism of pH-mediated stacking of anions for the analysis of physiological samples by capillary electrophoresis [J].
Arnett, SD ;
Lunte, CE .
ELECTROPHORESIS, 2003, 24 (11) :1745-1752
[3]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[4]   Velocity-difference induced focusing of nucleotides in capillary electrophoresis with a dynamic pH junction [J].
Britz-McKibbin, P ;
Bebault, GM ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1729-1735
[5]   Quantitative predictions to conditions of zwitterionic stacking by transient moving chemical reaction boundary created with weak electrolyte buffers in capillary electrophoresis [J].
Cao, CX ;
Zhang, W ;
Qin, WH ;
Li, S ;
Zhu, W ;
Liu, W .
ANALYTICAL CHEMISTRY, 2005, 77 (04) :955-963
[6]   Improving separation efficiency of capillary zone electrophoresis of tryptophan and phenylalanine with the transient moving chemical reaction boundary method [J].
Cao, CX ;
He, YZ ;
Li, M ;
Qian, YT ;
Yang, L ;
Qu, QS ;
Zhou, SL ;
Chen, WK .
JOURNAL OF CHROMATOGRAPHY A, 2002, 952 (1-2) :39-46
[7]   Stacking ionizable analytes in a sample matrix with high salt by a transient moving chemical reaction boundary, method in capillary zone electrophoresis [J].
Cao, CX ;
He, YZ ;
Li, M ;
Qian, YT ;
Gao, MF ;
Ge, LH ;
Zhou, SL ;
Yang, L ;
Qu, QS .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4167-4174
[8]   Experimental investigation on moving chemical reaction boundary theory for weak-acid-strong-base system with background electrolyte KCl in large concentration [J].
Cao, CX ;
Zhou, SL ;
Qian, YT ;
He, YZ ;
Yang, L ;
Qu, QS ;
Chen, WK .
JOURNAL OF CHROMATOGRAPHY A, 2001, 922 (1-2) :283-292
[9]   Corrections to moving chemical reaction boundary equation for weak reactive electrolytes under the existence of background electrolyte KC1 in large concentrations [J].
Cao, CX ;
Zhou, SL ;
He, YZ ;
Qian, YT ;
Yang, L ;
Qu, QS ;
Gan, WE ;
Dong, L ;
Zhao, YQ ;
Chen, WK .
JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) :347-352
[10]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050