Isotachophoresis preconcentration integrated microfluidic chip for highly sensitive genotyping of the hepatitis B virus

被引:42
作者
Liu, Dayu
Shi, Ming
Huang, Huaiqing
Long, Zhicheng
Zhou, Xiaomian
Qin, Jianhua
Lin, Bingcheng [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dept Biotechnol, Dalian 116023, Peoples R China
[2] Dalian Univ Technol, Dept Biotechnol, Dalian 116023, Peoples R China
[3] Guangzhou First Municipal Peoples Hosp, Dept Clin Lab, Guangzhou Med Coll, Guangzhou 510500, Peoples R China
[4] Chinese Acad Sci, Grad Sch, Beijing 100000, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 844卷 / 01期
关键词
microfluidic chip; sample preconcentration; isotachophoresis; hepatitis virus B; genotyping;
D O I
10.1016/j.jchromb.2006.06.041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The genotyping of hepatitis B virus (HBV) has become recently a valuable tool not only for epidemiological reasons but also for the clinical practice. Conventional methods for HBV genotyping typically include amplification of the target DNA sequences with a two-round nested PCR followed by separation of the amplified fragments by gel electrophoresis. A microfluidic chip that couples isotachophoresis (ITP) preconcentration and zone electrophoresis (ZE) separation may provide great advantages for sensitive, rapid and cost-effective clinical analysis. In this study, an HBV genotyping method with only one amplification round was developed by the application of the ITP-ZE chip. All the analysis steps of the ITP-ZE separation including sample injection, stacking and separation were performed continuously, controlled by sequential high-voltage switching. A 2.1 cm sample plug was preconcentrated between discontinuous buffers in ITP process, followed by ZE separation. Sensitivity enhancement was obtained through the increase of sample loading volume. The average LOD value of the ITP-ZE microfluidic chip was determined to be 0.0021 pg/mu L. In a large-scale HBV genotyping test, single round PCR products were analyzed by ITP-ZE microfluidic chip, and the results were compared with that of the conventional method. Among the 200 cases studied, the classification rate obtained with microfluidic chip was 93%, which was 6% higher than that obtained with the conventional method. Method with ITP-ZE chip analysis provides HBV genotyping information in reduced PCR amplification time with higher detection rate when compared with conventional method. This method holds great potential for extrapolation to the abundance of similar molecular biology-based techniques in clinical diagnosis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 27 条
[1]   Influence of hepatitis B virus genotypes on the response to antiviral therapies [J].
Akuta, N ;
Kumada, H .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2005, 55 (02) :139-142
[2]   Genotype C hepatitis B virus infection is associated with an increased risk of hepatocellular carcinoma [J].
Chan, HLY ;
Hui, AY ;
Wong, ML ;
Tse, AML ;
Hung, LCT ;
Wong, VWS ;
Sung, JJY .
GUT, 2004, 53 (10) :1494-1498
[3]  
Chen CH, 2004, HEPATO-GASTROENTEROL, V51, P552
[4]   Genotype C hepatitis B virus infection is associated with a higher risk of reactivation of hepatitis B and progression to cirrhosis than genotype B: A longitudinal study of hepatitis B e antigen-positive patients with normal aminotransferase levels at baseline [J].
Chu, CM ;
Liaw, YF .
JOURNAL OF HEPATOLOGY, 2005, 43 (03) :411-417
[5]   Response to interferon alfa is hepatitis B virus genotype dependent:: genotype A is more sensitive to interferon than genotype D [J].
Erhardt, A ;
Blondin, D ;
Hauck, K ;
Sagir, A ;
Kohnle, T ;
Heintges, T ;
Häussinger, D .
GUT, 2005, 54 (07) :1009-1013
[6]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[7]  
Hempel G, 2000, ELECTROPHORESIS, V21, P691, DOI 10.1002/(SICI)1522-2683(20000301)21:4<691::AID-ELPS691>3.3.CO
[8]  
2-L
[9]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[10]   On-line isotachophoretic preconcentration and gel electrophoretic separation of sodium dodecyl sulfate-proteins on a microchip [J].
Huang, HQ ;
Xu, F ;
Dai, ZP ;
Lin, BC .
ELECTROPHORESIS, 2005, 26 (11) :2254-2260