Optimization of the high-performance liquid chromatographic separation of a complex mixture containing urinary steroids, boldenone and bolasterone: application to urine samples

被引:32
作者
Gonzalo-Lumbreras, R [1 ]
Izquierdo-Hornillos, R [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 742卷 / 01期
关键词
urinary steroids; boldenone; bolasterone;
D O I
10.1016/S0378-4347(00)00084-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An HPLC separation of a complex mixture containing 13 urinary anabolics and corticoids, and boldenone and bolasterone (synthetic anabolics) has been carried out. The applied optimization method involved the use of binary, ternary and quaternary mobile phases containing acetonitrile, methanol or tetrahydrofuran as organic modifiers. The effect of different reversed-phase packings and temperature on the separation was studied. The optimum separation was achieved by using a water-acetonitrile (60:40, v/v) mobile phase in reversed-phase HPLC at 30 degrees C, allowing the separation of all the analytes in about 24 min. Calibration graphs were obtained using bolasterone or methyltestosterone as internal standards. Detection limits were in the range 0.012-0.107 mu g ml(-1). The optimized separation was applied to the analysis, after liquid-liquid extraction, of human urine samples spiked with steroids. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 26 条
[1]  
Aguilera R, 1996, J MASS SPECTROM, V31, P169, DOI 10.1002/(SICI)1096-9888(199602)31:2<169::AID-JMS276>3.0.CO
[2]  
2-I
[3]   DETERMINATION OF STEROIDS IN URINE BY MICELLAR HPLC WITH DETECTION BY SENSITIZED TERBIUM FLUORESCENCE [J].
AMIN, M ;
HARRINGTON, K ;
VONWANDRUSZKA, R .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2346-2351
[4]   Testing for natural and synthetic anabolic agents in human urine [J].
Ayotte, C ;
Goudreault, D ;
Charlebois, A .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :3-25
[5]  
CARLSTROM K, 1992, CLIN CHEM, V38, P1779
[6]   ONLINE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DIODE-ARRAY SPECTROPHOTOMETRIC ANALYSIS OF STEROIDAL HORMONES IN ILLEGAL PREPARATIONS [J].
DEBEER, JO .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01) :139-155
[7]   LONG-TERM ADMINISTRATION OF TESTOSTERONE ENANTHATE TO NORMAL MEN - ALTERATIONS OF THE URINARY PROFILE OF ANDROGEN METABOLITES POTENTIALLY USEFUL FOR DETECTION OF TESTOSTERONE MISUSE IN SPORT [J].
DEHENNIN, L ;
MATSUMOTO, AM .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1993, 44 (02) :179-189
[8]   Increased urinary testosterone epitestosterone ratios found in Swedish athletes in connection with a national control program - Evaluation of 28 cases [J].
Garle, M ;
Ocka, R ;
Palonek, E ;
Bjorkhem, I .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :55-59
[9]  
*INT OL COMM MED C, 1995, LIST DOP CLASS METH
[10]  
KAPLAN LA, 1989, CLIN CHEM