Development and characteristics of polymer monoliths for advanced LC bioscreening applications: A review

被引:39
作者
Acquah, Caleb [1 ,2 ]
Moy, Charles K. S. [3 ]
Danquah, Michael K. [1 ,2 ]
Ongkudon, Clarence M. [4 ]
机构
[1] Curtin Univ, Curtin Sarawak Res Inst, Sarawak 98009, Malaysia
[2] Curtin Univ, Dept Chem Engn, Sarawak 98009, Malaysia
[3] Xian Jiaotong Liverpool Univ, Dept Civil Engn, Xian 215123, Jiangsu, Peoples R China
[4] Univ Malaysia Sabah, Biotechnol Res Inst, Kota Kinabalu 88400, Sabah, Malaysia
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2016年 / 1015卷
关键词
Monoliths; Polymethacrylate; Bio-screening; Chromatography; Polymerisation; Biomolecules; PERFORMANCE LIQUID-CHROMATOGRAPHY; METHACRYLATE-BASED MONOLITHS; LARGE SURFACE-AREA; AFFINITY-CHROMATOGRAPHY; SEPARATION EFFICIENCY; SELECTIVE EXTRACTION; CAPILLARY COLUMNS; STATIONARY PHASES; SMALL MOLECULES; PRESSURE-DROP;
D O I
10.1016/j.jchromb.2016.02.016
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Biomedical research advances over the past two decades in bioseparation science and engineering have led to the development of new adsorbent systems called monoliths, mostly as stationary supports for liquid chromatography (LC) applications. They are acknowledged to offer better mass transfer hydrodynamics than their particulate counterparts. Also, their architectural and morphological traits can be tailored in situ to meet the hydrodynamic size of molecules which include proteins, pDNA, cells and viral targets. This has enabled their development for a plethora of enhanced bioscreening applications including biosensing, biomolecular purification, concentration and separation, achieved through the introduction of specific functional moieties or ligands (such as triethylamine, N,N-dimethyl-N-dodecylamine, antibodies, enzymes and aptamers) into the molecular architecture of monoliths. Notwithstanding, the application of monoliths presents major material and bioprocess challenges. The relationship between in-process polymerisation characteristics and the physicochemical properties of monolith is critical to optimise chromatographic performance. There is also a need to develop theoretical models for non-invasive analyses and predictions. This review article therefore discusses in-process analytical conditions, functionalisation chemistries and ligands relevant to establish the characteristics of monoliths in order to facilitate a wide range of enhanced bioscreening applications. It gives emphasis to the development of functional polymethacrylate monoliths for microfluidic and preparative scale bio-applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 134
页数:14
相关论文
共 136 条
[1]
A review on immobilised aptamers for high throughput biomolecular detection and screening [J].
Acquah, Caleb ;
Danquah, Michael K. ;
Yon, John L. S. ;
Sidhu, Amandeep ;
Ongkudon, Clarence M. .
ANALYTICA CHIMICA ACTA, 2015, 888 :10-18
[2]
Characterization of oligosorbents and application to the purification of ochratoxin A from wheat extracts [J].
Ali, Wassim Hadj ;
Pichon, Valerie .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (04) :1233-1240
[3]
Fabrication and evaluation of an organic monolithic column based upon the polymerisation of hexyl methacrylate with 1,6-hexanediol ethoxylate diacrylate for the separation of small molecules by capillary liquid chromatography [J].
Alshitari, Wael ;
Quigley, Cristina Legido ;
Smith, Norman .
TALANTA, 2015, 141 :103-110
[4]
Conceptual Design of Large Surface Area Porous Polymeric Hybrid Media Based on Polyhedral Oligomeric Silsesquioxane Precursors: Preparation, Tailoring of Porous Properties, and Internal Surface Functionalization [J].
Alves, Filipa ;
Scholder, Pascal ;
Nischang, Ivo .
ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (07) :2517-2526
[5]
Pipette-tip selective extraction of glycoproteins with lectin modified gold nano-particles on a polymer monolithic phase [J].
Alwael, Hassan ;
Connolly, Damian ;
Clarke, Paul ;
Thompson, Roisin ;
Twamley, Brendan ;
O'Connor, Brendan ;
Paull, Brett .
ANALYST, 2011, 136 (12) :2619-2628
[6]
[Anonymous], CRIT REV BIOTECHNOL
[7]
[Anonymous], 2012, CHEM SENSORS BIOSENS
[8]
[Anonymous], 2005, Handbook of Affinity Chromatography
[9]
Chromatography of microbial cells using continuous supermacroporous affinity and ion-exchange columns [J].
Arvidsson, P ;
Plieva, FM ;
Savina, IN ;
Lozinsky, VI ;
Fexby, S ;
Bülow, L ;
Galaev, IY ;
Mattiasson, B .
JOURNAL OF CHROMATOGRAPHY A, 2002, 977 (01) :27-38
[10]
A new anion-exchange/hydrophobic monolith as stationary phase for nano liquid chromatography of small organic molecules and inorganic anions [J].
Aydogan, Cemil .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1392 :63-68