Arbitrary precision in multipath interferometry

被引:32
作者
DAriano, GM
Paris, MGA
机构
[1] Istituto Nazionale di Fisica della Materia, Sezione di Pavia, Pavia, I-27100
来源
PHYSICAL REVIEW A | 1997年 / 55卷 / 03期
关键词
D O I
10.1103/PhysRevA.55.2267
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Interferometers with M paths are studied. It is shown that the accuracy of the phase-shift measurement can be improved by increasing the number of paths. For a detection scheme that uses coherent input states, phase sensitivity rescales as Delta phi proportional to M(-1). and nonunit quantum efficiency eta at detectors only decreases the effective M by a factor root pi.
引用
收藏
页码:2267 / 2271
页数:5
相关论文
共 19 条
[1]   4TH-ORDER INTERFERENCE OF JOINT SINGLE-PHOTON WAVE-PACKETS IN LOSSLESS OPTICAL-SYSTEMS [J].
CAMPOS, RA ;
SALEH, BEA ;
TEICH, MC .
PHYSICAL REVIEW A, 1990, 42 (07) :4127-4137
[2]   QUANTUM-MECHANICAL NOISE IN AN INTERFEROMETER [J].
CAVES, CM .
PHYSICAL REVIEW D, 1981, 23 (08) :1693-1708
[3]   THE RING LASER GYRO [J].
CHOW, WW ;
GEABANACLOCHE, J ;
PEDROTTI, LM ;
SANDERS, VE ;
SCHLEICH, W ;
SCULLY, MO .
REVIEWS OF MODERN PHYSICS, 1985, 57 (01) :61-104
[4]   2-MODE HETERODYNE PHASE DETECTION [J].
DARIANO, GM ;
SACCHI, MF .
PHYSICAL REVIEW A, 1995, 52 (06) :R4309-R4312
[5]   LOWER BOUNDS ON PHASE SENSITIVITY IN IDEAL AND FEASIBLE MEASUREMENTS [J].
DARIANO, GM ;
PARIS, MGA .
PHYSICAL REVIEW A, 1994, 49 (04) :3022-3036
[6]   Feedback-assisted homodyne detection of phase shifts [J].
DAriano, GM ;
Paris, MGA ;
Seno, R .
PHYSICAL REVIEW A, 1996, 54 (05) :4495-4504
[7]   3-BEAM INTERFEROMETER [J].
HARIHARAN, P ;
SEN, D .
JOURNAL OF SCIENTIFIC INSTRUMENTS, 1959, 36 (02) :70-72
[8]  
MATTLE K, 1995, APPL PHYS B-LASERS O, V60, pS111
[9]   MEASUREMENT OF THE QUANTUM PHASE BY PHOTON-COUNTING [J].
NOH, JW ;
FOUGERES, A ;
MANDEL, L .
PHYSICAL REVIEW LETTERS, 1991, 67 (11) :1426-1429
[10]   SMALL AMOUNT OF SQUEEZING IN HIGH-SENSITIVE REALISTIC INTERFEROMETRY [J].
PARIS, MGA .
PHYSICS LETTERS A, 1995, 201 (2-3) :132-138