High-resolution gadolinium-enhanced 3D MRA of the infrapopliteal arteries: Lessons for improving bolus-chase peripheral MRA

被引:15
作者
Hood, MN [1 ]
Ho, VB
Foo, TKF
Marcos, HB
Hess, SL
Choyke, PL
机构
[1] Uniformed Serv Univ Hlth Sci, Dept Radiol, Bethesda, MD 20814 USA
[2] NIH, Warren G Magnuson Clin Ctr, Dept Diagnost Radiol, Bethesda, MD 20892 USA
[3] GE Co, Med Syst, Appl Sci Lab, Milwaukee, WI 53201 USA
关键词
magnetic resonance angiography; magnetic resonance imaging; peripheral arteries; contrast media; gadolinium;
D O I
10.1016/S0730-725X(02)00531-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Peripheral magnetic resonance angiography (MRA) is growing in use. However, methods of performing peripheral MRA vary widely and continue to be optimized, especially for improvement in illustration of infrapopliteal arteries. The main purpose of this project was to identify imaging factors that can improve arterial visualization in the lower leg using bolus chase peripheral MRA. Eighteen healthy adults were imaged on a 1.5T MR scanner. The calf was imaged using conventional three-station bolus chase three-dimensional (3D) MRA, two dimensional (2D) time-of-flight (TOF) MRA and single-station Gadolinium (Gd)-enhanced 3D MRA. Observer comparisons of vessel visualization, signal to noise ratios (SNR), contrast to noise ratios (CNR) and spatial resolution comparisons were performed. Arterial SNR and CNR were similar for all three techniques. However, arterial visualization was dramatically improved on dedicated, arterial-phase Gd-enhanced 3D MRA compared with the multi-station bolus chase MRA and 2D TOF MRA. This improvement was related to optimization of Gd-enhanced 3D MRA parameters (fast injection rate of 2 mL/sec, high spatial resolution imaging, the use of dedicated phased array coils, elliptical centric k-space sampling and accurate arterial phase timing for image acquisition). The visualization of the infrapopliteal arteries can be substantially improved in bolus chase peripheral MRA if voxel size, contrast delivery, and central k-space data acquisition for arterial enhancement are optimized. Improvements in peripheral MRA should be directed at these parameters. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 21 条
  • [1] MAGNETIC-RESONANCE ANGIOGRAPHY AND MEASUREMENT OF BLOOD-FLOW IN THE PERIPHERAL VESSELS
    CAPUTO, GR
    HIGGINS, CB
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 : S97 - S102
  • [2] Czum JM, 2000, J MAGN RESON IMAGING, V12, P769, DOI 10.1002/1522-2586(200011)12:5<769::AID-JMRI16>3.3.CO
  • [3] 2-J
  • [4] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [5] Optimization of contrast timing for breath-hold three-dimensional MR angiography
    Hany, TF
    McKinnon, GC
    Leung, DA
    Pfammatter, T
    Debatin, JF
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 551 - 556
  • [6] Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography
    Ho, KYJAM
    Leiner, T
    de Haan, MW
    Kessels, AGH
    Kitslaar, PJEHM
    van Engelshoven, JMA
    [J]. RADIOLOGY, 1998, 206 (03) : 683 - 692
  • [7] Ho VB, 1999, JMRI-J MAGN RESON IM, V10, P376, DOI 10.1002/(SICI)1522-2586(199909)10:3<376::AID-JMRI20>3.0.CO
  • [8] 2-U
  • [9] Two-dimensional time-of-flight MR angiography of the lower extremities: Artifacts and pitfalls
    Kaufman, JA
    McCarter, D
    Geller, SC
    Waltman, AC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 129 - 135
  • [10] Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, E
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 345 - 348