Development and validation of a multiwavelength spatial domain near-infrared oximeter to detect cerebral hypoxia-ischemia

被引:27
作者
Nelson, Lindsey A.
McCann, John C.
Loepke, Andres W.
Wu, Jun
Ben Dor, Baruch
Kurth, C. Dean
机构
[1] Univ Cincinnati, Childrens Hosp, Med Ctr, Coll Med,Dept Anesthesia & Pediat,Inst Pediat Ane, Cincinnati, OH 45229 USA
[2] Near Infrared Monitoring Inc, Philadelphia, PA 19104 USA
关键词
biology; medicine; optical devices; photodetectors; spectroscopy;
D O I
10.1117/1.2393251
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Detection of cerebral hypoxia-ischemia in infants remains problematic, as current monitors in clinical practice are impractical, insensitive, or nonspecific. Our study develops a multiwavelength spatial domain construct for near-infrared spectroscopy (NIRS) to detect cerebral hypoxia-ischemia and evaluates the construct in several models. The NIRS probe contains photodiode detectors 2, 3, and 4 cm from a three-wavelength, light-emitting diode. A construct determines cerebral O-2 saturation based on spatial domain principles. Device performance and construct validity are examined in in-vitro models simulating the brain, and in piglets subjected to hypoxia, hypoxia-ischemia, and hyperoxic conditions using a weighted average of arterial and cerebral venous O-2 saturation measured by CO-oximetry. The results in the brain models verify key equations in the construct and demonstrate reliable performance of the device. In piglets, the device measures cerebral O-2 saturation with bias +/- 4% and precision +/- 8%. In conclusion, this NIRS device accurately detects cerebral hypoxia-ischemia and is of a design that is practical for clinical application. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:8
相关论文
共 29 条
[1]   THE THEORETICAL BASIS FOR THE DETERMINATION OF OPTICAL PATHLENGTHS IN TISSUE - TEMPORAL AND FREQUENCY-ANALYSIS [J].
ARRIDGE, SR ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) :1531-1560
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Near-infrared monitoring of cerebral tissue oxygen saturation and blood volume in newborn piglets [J].
Brun, NC ;
Moen, A ;
Borch, K ;
Saugstad, OD ;
Greisen, G .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 273 (02) :H682-H686
[4]   Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry [J].
Daubeney, PEF ;
Pilkington, SN ;
Janke, E ;
Charlton, GA ;
Smith, DC ;
Webber, SA .
ANNALS OF THORACIC SURGERY, 1996, 61 (03) :930-934
[5]   ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT [J].
DELPY, DT ;
COPE, M ;
VANDERZEE, P ;
ARRIDGE, S ;
WRAY, S ;
WYATT, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) :1433-1442
[6]   Measurement of cerebral oxygenation state in anaesthetized children using the INVOS 5100 cerebral oximeter [J].
Dullenkopf, A ;
Frey, B ;
Baenziger, O ;
Gerber, A ;
Weiss, M .
PAEDIATRIC ANAESTHESIA, 2003, 13 (05) :384-391
[7]  
Edmonds Harvey L Jr, 2003, Curr Opin Crit Care, V9, P98
[8]   Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy [J].
Fantini, S ;
Hueber, D ;
Franceschini, MA ;
Gratton, E ;
Rosenfeld, W ;
Stubblefield, PG ;
Maulik, D ;
Stankovic, MR .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (06) :1543-1563
[9]   Principles, techniques, and limitations of near infrared spectroscopy [J].
Ferrari, M ;
Mottola, L ;
Quaresima, V .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2004, 29 (04) :463-487
[10]   Medical progress - Neonatal brain injury [J].
Ferriero, DM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (19) :1985-1995