Quantifying catecholamines using multi-way kinetic modelling

被引:61
作者
Nikolajsen, RPH
Booksh, KS
Hansen, ÅM
Bro, R
机构
[1] Natl Inst Occupat Hlth, Copenhagen, Denmark
[2] Royal Vet & Agr Univ, Chemometr Grp, Copenhagen, Denmark
[3] Arizona State Univ, Dept Biochem & Chem, Tempe, AZ 85287 USA
关键词
catecholamines; PARAFAC; kinetics; trihydroxyindole; urine; stress;
D O I
10.1016/S0003-2670(02)01256-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for quantifying adrenaline and noradrenaline concentrations from mixtures of catecholamine standards is described. The method derives selectivity from the different rates, at which the fluorescing 3,5,6-trihydroxyindole derivatives (lutines) of the catecholamines are formed and degraded for adrenaline and noradrenaline. The standards used had the concentration ranges 50-1200 nmol/l for adrenaline and 30-1400 nmol/l for noradrenaline. Fluorescence landscapes were measured at consecutive time points for every sample hereby creating a four-way data array. It is shown that the raw dataset can be dramatically reduced in size without loosing significant information hereby making calculations much faster and lessening instrumental performance requirements. The data follow a two-component four-way parallel factor analysis model (PARAFAC), from which quantitative information is also obtained. Two-component multilinear partial least squares regression (N-PLSR) was also employed for the quantification of the catecholamines. The results for PARAFAC and N-PLSR were very similar with root mean squared errors of cross-validation (RMSECV) being in the range 24-30 nmol/l. Several improvements of the method are suggested, and it is expected that the method will be suitable for determination of catecholamines in urine from healthy subjects. (C) 2002 Elsevier Science B:V. All rights reserved.
引用
收藏
页码:137 / 150
页数:14
相关论文
共 43 条
[1]  
[Anonymous], 1990, Journal ofChemometrics, DOI DOI 10.1002/CEM.1180040105
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]   EXTENSION OF TRILINEAR DECOMPOSITION METHOD WITH AN APPLICATION TO THE FLOW PROBE SENSOR [J].
BOOKSH, KS ;
LIN, ZH ;
WANG, ZY ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2561-2569
[4]   Single measurement excitation/emission matrix spectrofluorometer for determination of hydrocarbons in ocean water .2. Calibration and quantitation of naphthalene and styrene [J].
Booksh, KS ;
Muroski, AR ;
Myrick, ML .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3539-3544
[5]   DEVELOPMENT AND PERFORMANCE OF AN AUTOMATED HPLC-ANALYZER FOR CATECHOLAMINES [J].
BOOS, KS ;
WILMERS, B ;
SAUERBREY, R ;
SCHLIMME, E .
CHROMATOGRAPHIA, 1987, 24 :363-370
[6]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[7]   Exploratory study of sugar production using fluorescence spectroscopy and multi-way analysis [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :133-147
[8]   Enzymatic browning of vegetables. Calibration and analysis of variance by multiway methods [J].
Bro, R ;
Heimdal, H .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 34 (01) :85-102
[9]   On the difference between low-rank and subspace approximation: improved model for multi-linear PLS regression [J].
Bro, R ;
Smilde, AK ;
de Jong, S .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 58 (01) :3-13
[10]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO