Improved results using extensively coated THA stems at minimum 5-year followup

被引:6
作者
Callaghan, John J. [1 ]
Templeton, Jesse E. [1 ]
Liu, Steve S. [1 ]
Warth, Lucian C. [1 ]
Chung, Young-Yool [1 ]
机构
[1] Univ Iowa Hlth Care, Dept Orthopaed, Iowa City, IA 52242 USA
关键词
D O I
10.1097/01.blo.0000238850.23744.58
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Prodigy(R) femoral component was extensively coated along its entire length, except for a smooth bullet-shaped distal tip. At a minimum 5 year followup we compared the results of that stem to those of a proximally coated first generation femoral component at comparable followup to address the question of which design performed better. For the extensively coated cohort, 86 patients (100 hips) underwent total hip arthroplasty by a single surgeon. At final followup, no patients were lost to followup and no hips were revised for aseptic loosening. Clinically, 3% of patients reported thigh pain (versus 15% in the proximally coated group). Radiographically, all hips had evidence of bone ingrowth (versus 94% in the PCA group). As expected with an extensively coated device there were fewer radiolucencies around the lower half of the prosthesis as well as less distal femoral lysis compared to the proximally coated stem.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 11 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
Bellamy N, 1997, J RHEUMATOL, V24, P2413
[3]
The odyssey of porous-coated fixation [J].
Engh, CA ;
Hopper, RH .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :102-107
[4]
Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty [J].
Engh, CA ;
Culpepper, WJ ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (02) :177-184
[5]
Engh CA., 1990, CLIN ORTHOP RELAT R, V257, P107
[6]
ENGH CA, 1988, CLIN ORTHOP RELAT R, V231, P7
[7]
Cross-validation of item selection and scoring for the SF-12 Health Survey in nine countries: Results from the IQOLA Project [J].
Gandek, B ;
Ware, JE ;
Aaronson, NK ;
Apolone, G ;
Bjorner, JB ;
Brazier, JE ;
Bullinger, M ;
Kaasa, S ;
Leplege, A ;
Prieto, L ;
Sullivan, M .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1998, 51 (11) :1171-1178
[8]
THE POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS, INSERTED WITHOUT CEMENT - RESULTS AFTER 5 TO 7 YEARS IN A PROSPECTIVE-STUDY [J].
HEEKIN, RD ;
CALLAGHAN, JJ ;
HOPKINSON, WJ ;
SAVORY, CG ;
XENOS, JS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) :77-91
[9]
CLINICAL AND RADIOGRAPHIC EVALUATION OF TOTAL HIP-REPLACEMENT - A STANDARD SYSTEM OF TERMINOLOGY FOR REPORTING RESULTS [J].
JOHNSTON, RC ;
FITZGERALD, RH ;
HARRIS, WH ;
POSS, R ;
MULLER, ME ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (02) :161-168
[10]
Kronick JL, 1997, CLIN ORTHOP RELAT R, P263