Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging

被引:205
作者
Kim, SG
Tsekos, NV
机构
[1] Ctr. for Magnetic Resonance Research, Department of Radiology, Univ. of Minnesota Medical School, Minneapolis, MN
[2] CMRR, Univ. of Minnesota Medical School, Minneapolis, MN 55455
关键词
cerebral blood flow; perfusion; functional magnetic resonance imaging; functional brain mapping;
D O I
10.1002/mrm.1910370321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Perfusion is a crucial physiological parameter for tissue function. To obtain perfusion-weighted images and consequently to measure cerebral blood flow (CBF), a newly developed flow-sensitive alternating inversion recovery (FAIR) technique was used. Dependency of FAIR signal on inversion times (TI) was examined; signal is predominantly located in large vessels at short TI, whereas it is diffused into gray matter areas at longer TI. CBF of gray matter areas in the human brain is 71 +/- 15 SD ml/100 g/min (n = 6). In fMRI studies, micro- and macrovessel inflow contributions can be obtained by adjusting TIs. Signal changes in large vessel areas including the scalp were seen during finger opposition at a TI of 0.4 s; however, these were not observed at a longer TI of 1.4 s. To compare with commonly used BOLD and slice selective inversion recovery techniques, FAIR and BOLD images were acquired at the same time during unilateral finger opposition, Generally, activation sites determined by three techniques are consistent. However, activation of some areas can be detected only by FAIR, not by BOLD, suggesting that the oxygen consumption increase couples with the CBF change completely. Relative and absolute CBF changes in the contralateral motor cortex are 53 +/- 17% SD (n = 9) and 27 +/- 11 SD ml/100 g/min (n = 9), respectively.
引用
收藏
页码:425 / 435
页数:11
相关论文
共 44 条
[1]  
ACKERMAN JJH, 1987, P NATL ACAD SCI USA, V85, P4099
[2]  
ADRIANY G, 1995, P SMR 3 ANN M, P747
[3]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[4]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[5]   REGIONAL CEREBRAL BLOOD-FLOW DURING VOLUNTARY ARM AND HAND MOVEMENTS IN HUMAN-SUBJECTS [J].
COLEBATCH, JG ;
DEIBER, MP ;
PASSINGHAM, RE ;
FRISTON, KJ ;
FRACKOWIAK, RSJ .
JOURNAL OF NEUROPHYSIOLOGY, 1991, 65 (06) :1392-1401
[6]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[7]  
DORMAN SD, 1995, MAGNET RESON MED, V3, P636
[8]  
DUYN JH, 1994, NMR BIOMED, V7, P4
[9]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[10]   CONCURRENT MEASUREMENTS OF CEREBRAL BLOOD-FLOW, SODIUM, LACTATE, AND HIGH-ENERGY PHOSPHATE-METABOLISM USING F-19, NA-23, H-1, AND P-31 NUCLEAR MAGNETIC-RESONANCE SPECTROSCOPY [J].
ELEFF, SM ;
SCHNALL, MD ;
LIGETTI, L ;
OSBAKKEN, M ;
SUBRAMANIAN, VH ;
CHANCE, B ;
LEIGH, JS .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (04) :412-424