A novel and simple method for endotracheal intubation of mice

被引:48
作者
Spoelstra, E. N.
Ince, C.
Koeman, A.
Emons, V. M.
Brouwer, L. A.
van Luyn, M. J. A.
Westerink, B. H. C.
Remie, R.
机构
[1] Univ Groningen, Ctr Pharm, Dept Biomonitoring & Sensoring, NL-9700 AB Groningen, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Physiol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Groningen, Med Ctr, Med Biol Sect, Dept Pathol & Lab Med, NL-9700 AB Groningen, Netherlands
[4] Solvay Pharmaceut, Dept Lab Anim Sci, Weesp, Netherlands
[5] Int Microsurg Training Ctr, Lelystad, Netherlands
关键词
general anaesthesia; mechanical ventilation; endotracheal intubation; inhalation anaesthetics; laryngoscopic blade; mice;
D O I
10.1258/002367707779399400
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 [兽医学];
摘要
Endotracheal intubation in mice is necessary for experiments involving intratracheal instillation of various substances, repeated pulmonary function assessments and mechanical ventilation. Previously described methods for endotracheal intubation in mice require the use of injection anaesthesia to immobilize the animal during the intubation procedure or the use of a volatile anaesthetic prior to intubation for immobilization. With these methods, the control of anaesthetic depth during the intubation procedure is absent. We describe a method for simple and rapid intratracheal intubation in mice for mechanical ventilation, using a self-built plastic support to facilitate the intubation procedure. General anaesthesia is maintained by means of inhalation through a non-rebreathing circuit connected to the plastic support. This set-up gives the operator control of anaesthetic depth and sufficient time to perform the intubation procedure. A purpose-made laryngoscopic blade is used to facilitate the intubation tube entering the trachea. The blade of the purpose-made laryngoscope is constructed as a retraction guide and is curved for easy handling. Under direct vision, the epiglottis is gently lifted by the laryngoscopic blade while the intubation tube is pushed into the trachea. Following this novel intubation technique, we were able to mechanically ventilate mice for at least 2 h without severely disturbing blood gases. Histological evaluation of the lungs and microscopic evaluation of the trachea and larynx showed no signs of trauma related to the intubation technique or mechanical ventilation.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 20 条
[1]
[Anonymous], 1993, Lab Anim, V27, P1
[2]
In vivo cardiac electrophysiology studies in the mouse [J].
Berul, CI ;
Aronovitz, MJ ;
Wang, PJ ;
Mendelsohn, ME .
CIRCULATION, 1996, 94 (10) :2641-2648
[3]
A method of endotracheal intubation and pulmonary functional assessment for repeated studies in mice [J].
Brown, RH ;
Walters, DM ;
Greenberg, RS ;
Mitzner, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) :2362-2365
[4]
COSTA DL, 1986, LAB ANIM SCI, V36, P256
[5]
CEREBROVASCULAR RESPONSES UNDER CONTROLLED AND MONITORED PHYSIOLOGICAL CONDITIONS IN THE ANESTHETIZED MOUSE [J].
DALKARA, T ;
IRIKURA, K ;
HUANG, Z ;
PANAHIAN, N ;
MOSKOWITZ, MA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1995, 15 (04) :631-638
[6]
DEYO DJ, 1999, ANESTH ANALG, V88, pS176
[7]
Flecknell P. A., 1996, LAB ANIMAL ANAESTHES
[8]
ANESTHESIA OF ANIMALS FOR BIOMEDICAL-RESEARCH [J].
FLECKNELL, PA .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (06) :885-894
[9]
In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry [J].
Georgakopoulos, D ;
Mitzner, WA ;
Chen, CH ;
Byrne, BJ ;
Millar, HD ;
Hare, JM ;
Kass, DA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (04) :H1416-H1422
[10]
Guo YR, 1998, AM J PHYSIOL-HEART C, V275, pH1375