What results in fretting wear on polished femoral stems

被引:26
作者
Blunt, Liam A. [1 ]
Zhang, H. [1 ]
Barrans, Simon M. [1 ]
Jiang, X. [1 ]
Brown, Leigh T. [1 ]
机构
[1] Univ Huddersfield, Sch Comp & Engn, Ctr Precis Technol, Huddersfield HD1 3DH, W Yorkshire, England
关键词
Fretting wear; Total hip replacement; Finite element analysis; TOTAL HIP-REPLACEMENT; BONE-CEMENT POROSITY; INTERFACE; ARTHROPLASTIES; DEBRIS; COMPONENTS; PROSTHESES;
D O I
10.1016/j.triboint.2008.11.007
中图分类号
TH [机械、仪表工业];
学科分类号
120111 [工业工程];
摘要
Fretting wear on polished femoral stems has previously been observed in retrieval studies, and it is showing an increasing significance in the overall wear of cemented total hip replacement. However, the initiation and propagation process of this wear has not been fully understood, with shrinkage bumps and micropores in the cement surface being potential participants. In the present study, these two factors are investigated through a finite element analysis to determine which contributed more to fretting wear. A 2D finite element model was created to represent the stem-cement interface, and physiological loading was applied on the femoral stem to Simulate the situation during patient walking. The analysis indicated that the functionality of the shrinkage bumps was incidental in comparison with the micropores as the relative micromotion between the femoral stem and the shrinkage bumps was significantly lower than that between the femoral stem and the micropores. Additionally, the influence of micropore size and loading level on generation of fretting wear was further investigated, and an effective method was proposed to retard fretting wear and to improve the survivorship of cemented total hip replacement. This study theoretically validated the potential contribution of the micropores to generation of fretting wear. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1605 / 1614
页数:10
相关论文
共 28 条
[1]
[Anonymous], 1992, TRIBOLOGY FRICTION W
[2]
LOCALIZED ENDOSTEAL BONE LYSIS IN RELATION TO THE FEMORAL COMPONENTS OF CEMENTED TOTAL HIP ARTHROPLASTIES [J].
ANTHONY, PP ;
GIE, GA ;
HOWIE, CR ;
LING, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :971-979
[3]
Porosity reduction in bone cement at the cement-stem interface [J].
Bishop, NE ;
Ferguson, S ;
Tepic, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :349-356
[4]
Reproduction of fretting wear at the stem-cement interface in total hip replacement [J].
Brown, L. ;
Zhang, H. ;
Blunt, L. ;
Barrans, S. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H8) :963-971
[5]
BROWN L, 2001, NAT MEAS C HARR UK N
[6]
Brown LT, 2006, THESIS U HUDDERSFIEL
[7]
Multi-technique characterization of retrieved bone cement from revised total hip arthroplasties [J].
Eliades, T ;
Papadopulos, JS ;
Eliades, G ;
Silikas, N ;
Watts, DC .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (11) :967-972
[8]
Wear of surface engineered metal-on-metal hip prostheses [J].
Fisher, J ;
Hu, XQ ;
Stewart, TD ;
Williams, S ;
Tipper, JL ;
Ingham, E ;
Stone, MH ;
Davies, C ;
Hatto, P ;
Bolton, J ;
Riley, M ;
Hardaker, C ;
Isaac, GH ;
Berry, G .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (03) :225-235
[9]
Geiger MH, 2001, CLIN ORTHOP RELAT R, P258
[10]
Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision [J].
Hatton, A ;
Nevelos, JE ;
Nevelos, AA ;
Banks, RE ;
Fisher, J ;
Ingham, E .
BIOMATERIALS, 2002, 23 (16) :3429-3440