Measurement of ohmic voltage losses in individual cells of a PEMFC stack

被引:96
作者
Mennola, T [1 ]
Mikkola, M [1 ]
Noponen, M [1 ]
Hottinen, T [1 ]
Lund, P [1 ]
机构
[1] Helsinki Univ Technol, Lab Adv Energy Syst, FIN-02015 Espoo, Finland
关键词
current interruption; ohmic loss; PEMFC; stack;
D O I
10.1016/S0378-7753(02)00391-9
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The ohmic voltage loss in a fuel cell can be determined with the current interruption method. The method was utilized to measure the ohmic voltage loss in an individual cell of a fuel cell stack. This was achieved by producing voltage transients and monitoring them with a digital oscilloscope connected in parallel with the individual cell. In this study, the method was applied to a small polymer electrolyte membrane fuel cell (PEMFC) stack in which different air supply levels were employed on the cathode side. In the case of higher air-feed rate, the results revealed an increase of ohmic losses in the middle of the stack by up to 21% at 400 mA cm(-2), compared to the unit cell with the lowest ohmic loss. This probably resulted from the decrease of membrane conductivity because of drying. Comparison to individual cell voltages showed that the decrease of conductivity would not be observed if only the individual cell voltages alone were measured. The total ohmic loss in the stack was measured using the same method to verify the reliability of the measurement system. The results indicate a good agreement between the total ohmic loss and the combined ohmic losses in the individual cells. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:261 / 272
页数:12
相关论文
共 9 条
[1]   IN-SITU MEMBRANE RESISTANCE MEASUREMENTS IN POLYMER ELECTROLYTE FUEL-CELLS BY FAST AUXILIARY CURRENT PULSES [J].
BUCHI, FN ;
MAREK, A ;
SCHERER, GG .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (06) :1895-1901
[2]   In-situ resistance measurements of Nafion(R) 117 membranes in polymer electrolyte fuel cells [J].
Buchi, FN ;
Scherer, GG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 404 (01) :37-43
[3]   Electrochemical impedance study of electrode-membrane assemblies in PEM fuel cells I.: Electro-oxidation of H2 and H2/CO mixtures on Pt-based gas-diffusion electrodes [J].
Ciureanu, M ;
Wang, H .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (11) :4031-4040
[4]   INVESTIGATION OF POROUS-ELECTRODES BY CURRENT INTERRUPTION - APPLICATION TO MOLTEN-CARBONATE FUEL-CELL CATHODES [J].
LAGERGREN, C ;
LINDBERGH, G ;
SIMONSSON, D .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (03) :787-797
[5]  
MIKKOLA M, 2001, THESIS HELSINKI U TE
[6]   Measurement of current distribution in a free-breathing PEMFC [J].
Noponen, M ;
Mennola, T ;
Mikkola, M ;
Hottinen, T ;
Lund, P .
JOURNAL OF POWER SOURCES, 2002, 106 (1-2) :304-312
[7]   APPLICATION OF AC-IMPEDANCE IN FUEL-CELL RESEARCH-AND-DEVELOPMENT [J].
SELMAN, JR ;
LIN, YP .
ELECTROCHIMICA ACTA, 1993, 38 (14) :2063-2073
[8]   Characterization of polymer electrolyte fuel cells using AC impedance spectroscopy [J].
Springer, TE ;
Zawodzinski, TA ;
Wilson, MS ;
Gottesfeld, S .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (02) :587-599
[9]   CURRENT INTERRUPTION INSTRUMENTATION AND APPLICATIONS [J].
WRUCK, WJ ;
MACHADO, RM ;
CHAPMAN, TW .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (03) :539-546