A picoliter chamber array for cell-free protein synthesis

被引:32
作者
Kinpara, T
Mizuno, R
Murakami, Y
Kobayashi, M
Yamaura, S
Hasan, Q
Morita, Y
Nakano, H
Yamane, T
Tamiya, E
机构
[1] Japan Adv Inst Sci & Technol, Sch Mat Sci, Tatsunokuchi, Ishikawa 9231292, Japan
[2] Nagoya Univ, Grad Sch Bioagr Sci, Chikusa Ku, Nagoya, Aichi 4648601, Japan
基金
日本学术振兴会;
关键词
cell-free/in-vitro protein synthesis; green fluorescent protein; picoliter chamber; polydimethoxyl siloxane (PDMS); protein chip;
D O I
10.1093/jb/mvh102
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
The completion of human genome sequencing has shifted the focus of research from genes to proteins. In this regard, a protein library chip has become a useful tool for cell-free protein synthesis. In this study, we attempted to make a highly-integrated protein chip from a DNA library using in vitro protein synthesis on a microchamber array fabricated by using PDMS (polydimethyl siloxane), a hydrophobic surface, and glass, a hydrophilic bottom substrate. These structural properties prevented cross-contamination among the chambers. The minimum volume capacity of the smallest chamber was about 1 pl. The total number of chambers per chip was 10,000 on one chip (capacity 150 pl) and 250,000 on two others (1 and 5 pl). Next, we attempted in vitro protein synthesis using this microchamber array. The fluorescence of Green Fluorescent Protein (GFP) expressed on the chamber was rapidly detected (within just 1 h). GFP expression was also successful using immobilized DNA molecules on polymer beads. DNA immobilized beads were added as the source to each microchamber. Protein was successfully synthesized from DNA immobilized beads, which allowed easy handling of the DNA molecules.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 26 条
[1]
Andreadis J D, 2000, Nucleic Acids Res, V28, pe5, DOI 10.1093/nar/28.2.e5
[2]
In vitro cloning of complex mixtures of DNA on microbeads:: Physical separation of differentially expressed cDNAs [J].
Brenner, S ;
Williams, SR ;
Vermaas, EH ;
Storck, T ;
Moon, K ;
McCollum, C ;
Mao, JI ;
Luo, SJ ;
Kirchner, JJ ;
Eletr, S ;
DuBridge, RB ;
Burcham, T ;
Albrecht, G .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (04) :1665-1670
[3]
Figeys D, 2001, ELECTROPHORESIS, V22, P208, DOI 10.1002/1522-2683(200101)22:2<208::AID-ELPS208>3.0.CO
[4]
2-O
[5]
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer [J].
Jo, BH ;
Van Lerberghe, LM ;
Motsegood, KM ;
Beebe, DJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) :76-81
[6]
Electrochemical protein chip with arrayed immunosensors with antibodies immobilized in a plasma-polymerized film [J].
Kojima, K ;
Hiratsuka, A ;
Suzuki, H ;
Yano, K ;
Ikebukuro, K ;
Karube, I .
ANALYTICAL CHEMISTRY, 2003, 75 (05) :1116-1122
[7]
Protein microarrays to detect protein-protein interactions using red and green fluorescent proteins [J].
Kukar, T ;
Eckenrode, S ;
Gu, YR ;
Lian, W ;
Megginson, M ;
She, JX ;
Wu, DH .
ANALYTICAL BIOCHEMISTRY, 2002, 306 (01) :50-54
[8]
Application of a microchamber array for DNA amplification using a novel dispensing method [J].
Matsubara, Y ;
Kobayashi, M ;
Morita, Y ;
Tamiya, E .
ARCHIVES OF HISTOLOGY AND CYTOLOGY, 2002, 65 (05) :481-488
[9]
Poly(dimethylsiloxane) as a material for fabricating microfluidic devices [J].
McDonald, JC ;
Whitesides, GM .
ACCOUNTS OF CHEMICAL RESEARCH, 2002, 35 (07) :491-499
[10]
Development of a microchamber array for picoliter PCR [J].
Nagai, H ;
Murakami, Y ;
Morita, Y ;
Yokoyama, K ;
Tamiya, E .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1043-1047