Intra-observer and inter-observer repeatability of Anterior Eye Segment analysis system (EAS-1000) in anterior chamber configuration

被引:11
作者
Lam, AKC [1 ]
Chan, R [1 ]
Woo, GC [1 ]
Pang, PCK [1 ]
Chiu, R [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Optometry & Radiog, Hong Kong, Hong Kong, Peoples R China
关键词
anterior chamber angle; anterior chamber depth; Scheimpflug principle;
D O I
10.1046/j.1475-1313.2002.00074.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background., Anterior chamber configuration can be assessed via optical or ultrasonic techniques. Scheimpflug photography is a non-invasive method measuring the anterior segment. The Anterior Eye Segment analysis system, EAS-1000, utilises the Scheimpflug principle and was found to have good repeatability. Previous repeatability studies, however, have had limitations in their design. The current study investigated the intra-observer and interobserver repeatability of the EAS-1000. Methods: Twenty-five healthy young subjects were recruited. The anterior chamber angles in different quadrants were measured by two examiners for interobserver analysis. The first examiner repeated the measurement at another session for intra-observer analysis. The 95% limits of agreement and intra-class correlation coefficient (ICC) were calculated. The anterior chamber depth was also measured and compared with ultrasound biometry. Results: The anterior chamber angle assessment demonstrated good intra-observer (ICC ranging from 0.77 to 0.90 for different quadrants) and interobserver (ICC ranging from 0.68 to 0.81 for different quadrants) repeatability. The 95% intra-observer limits of agreement were within 50. The 95% interobserver limits of agreement were within 6'. There was no significant difference between male and female subjects or among angles at different quadrants. The anterior chamber depth was found to be repeatable (ICC > 0.90) with 95% limits of agreement +/-0.1 mm. The anterior chamber depth was shallower than that obtained from ultrasound biometry. Conclusions: The EAS-100 is a non-invasive instrument which is repeatable for measuring the anterior chamber angle and depth. It provides quick results and is good for screening purposes. There is an under-estimation of anterior chamber depth, as previously reported.
引用
收藏
页码:552 / 559
页数:8
相关论文
共 24 条
[1]  
ALWARD WM, 2000, GLAUCOMA REQUISITES, P42
[2]  
[Anonymous], FDN CLIN RES APPL PR
[3]  
BAEZ KA, 1992, OPHTHALMIC SURG LAS, V23, P426
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
BOKER T, 1995, OPHTHALMIC RES, V27, P104
[6]  
Bosem M E, 1992, J Glaucoma, V1, P254, DOI 10.1097/00061198-199201040-00008
[7]   Anterior chamber angle biometry: quadrant variation, age change and sex difference [J].
Chen, HB ;
Kashiwagi, K ;
Yamabayashi, S ;
Kinoshita, T ;
Ou, B ;
Tsukahara, S .
CURRENT EYE RESEARCH, 1998, 17 (02) :120-124
[8]  
Devereux JG, 2000, ARCH OPHTHALMOL-CHIC, V118, P257
[9]  
Douthwaite WA, 1998, INVEST OPHTH VIS SCI, V39, P1727
[10]   The thickness of the aging human lens obtained from corrected scheimpflug images [J].
Dubbelman, M ;
Van der Heijde, GL ;
Weeber, HA .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (06) :411-416