Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine

被引:126
作者
Ringel, Florian [1 ]
Stoffel, Michael [1 ]
Stueer, Carsten [1 ]
Meyer, Bernhard [1 ]
机构
[1] Univ Bonn, Dept Neurosurg, D-5300 Bonn, Germany
关键词
internal fixator; minimally invasive spine surgery; percutaneous pedicle screw fixation; spinal stabilization;
D O I
10.1227/01.NEU.0000223505.07815.74
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: This study assessed the feasibility and safety of percutaneous posterior pedicle screw fixation for instabilities of the thoracic and lumbar spine, using standard instruments designed for the open approach and fluoroscopy. METHODS: All patients who underwent percutaneous posterior pedicle screw fixation of the thoracic and lumbar spine were studied retrospectively. Charts and operative notes were analyzed for epidemiological data, underlying spinal pathological features, and indications for stabilization, stabilized segments, number of implanted pedicle screws, surgical time, and complications. Postoperative computed tomographic scans were analyzed for screw position. RESULTS: From May 2002 through May 2005, 115 internal fixators were implanted percutaneously in 104 patients. A total of 488 pedicle screws were implanted, stabilizing 1 to 5 spinal motion segments. Median surgical time was 93 minutes. On postoperative computed tomographic scans, 87% of screw positions were rated good, 10% were rated acceptable, and 3% were rated unacceptable. A total of 11 revisions were necessary, 9 for misplaced screws and 2 for loosening of anchor bolts. Only two of the patients experienced new clinical symptoms (i.e., radicular pain) because of screw misplacement. No patients experienced new neurological deficits or other surgery-related morbidity. CONCLUSION: This study shows that percutaneous internal pedicle screw fixation using standard instruments is feasible and safe for posterior stabilization of the thoracic and lumbar spine. It is a straightforward alternative for open approaches or minimally invasive ones using navigation in conjunction with customized instruments. Accuracy of screw placement is similar to that reported for other techniques.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 34 条
[1]
Acosta Frank L Jr, 2005, Spine J, V5, P339, DOI 10.1016/j.spinee.2004.09.012
[2]
Beisse R, 2002, ORTHOPADE, V31, P413, DOI 10.1007/s00132-001-0285-6
[3]
Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[4]
THE ROLE OF EXTERNAL SPINAL SKELETAL FIXATION IN THE ASSESSMENT OF LOW-BACK DISORDERS [J].
ESSES, SI ;
BOTSFORD, DJ ;
KOSTUIK, JP .
SPINE, 1989, 14 (06) :594-601
[5]
ACCURACY OF PEDICLE SCREW PLACEMENT IN LUMBAR FUSIONS BY PLAIN RADIOGRAPHS AND COMPUTED-TOMOGRAPHY [J].
FARBER, GL ;
PLACE, HM ;
MAZUR, RA ;
JONES, DEC ;
DAMIANO, TR .
SPINE, 1995, 20 (13) :1494-1499
[6]
Minimally invasive lumbar fusion [J].
Foley, KT ;
Holly, LT ;
Schwender, JD .
SPINE, 2003, 28 (15) :S26-S35
[7]
Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results [J].
Foley, KT ;
Gupta, SK .
JOURNAL OF NEUROSURGERY, 2002, 97 (01) :7-12
[8]
Haaker R G, 1997, Eur Spine J, V6, P125
[9]
Thoracic pedicle screws: postoperative computerized tomography scanning assessment [J].
Heary, RF ;
Bono, CM ;
Black, M .
JOURNAL OF NEUROSURGERY, 2004, 100 (04) :325-331
[10]
The external fixator - A tool for evaluation of complex low back pain problems [J].
Heini, PF ;
Gahrich, U ;
Orler, R .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (01) :8-14