A new approach for enhancing performance of a gas turbine (case study: Khangiran refinery)

被引:51
作者
Farzaneh-Gord, Mahmood [1 ]
Deymi-Dashtebayaz, Mahdi [1 ]
机构
[1] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
关键词
Gas turbine; Inlet air cooling; Gas turbine efficiency improvement; Natural-gas pressure drop stations;
D O I
10.1016/j.apenergy.2009.04.017
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
There are various methods which are commercially available for turbine air inlet cooling aiming to improve gas turbine efficiency. In this study a new approach has been proposed to improve performance of a gas turbine. The approach has been applied to one of the Khangiran refinery gas turbines. The idea is to cool inlet air of the gas turbine by potential cooling capacity of the refinery natural-gas pressure drop station. The study is part of a comprehensive program aimed to enhance gas turbines performance of the Khangiran gas refinery. The results show that the gas turbine inlet air temperature could be reduced in range of 4-25 K and the performance could be improved in range of 1.5-5% for almost 10 months. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2750 / 2759
页数:10
相关论文
共 13 条
[1]   Optimum power boosting of gas turbine cycles with compressor inlet air refrigeration [J].
AitAli, MA .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1997, 119 (01) :124-130
[2]   The study of capacity enhancement of the Chabahar gas turbine installation using an absorption chiller [J].
Ameri, M ;
Hejazi, SH .
APPLIED THERMAL ENGINEERING, 2004, 24 (01) :59-68
[3]  
[Anonymous], 1991, INT GAS TURB AER EN, DOI DOI 10.1115/91-GT-329
[4]   Effects of evaporative inlet and aftercooling on the recuperated gas turbine cycle [J].
Bassily, AM .
APPLIED THERMAL ENGINEERING, 2001, 21 (18) :1875-1890
[5]  
CORTES PEC, 2003, GAS TURBINE INLET AI
[6]  
EI-Hadik, 1993, J Eng Gas Turb Power, V112, P590
[7]   Recoverable energy in natural gas pressure drop stations: A case study of the Khangiran gas refinery [J].
Farzaneh-Gord, Mahmood ;
Deymi-Dashtebayaz, Mahdi .
ENERGY EXPLORATION & EXPLOITATION, 2008, 26 (02) :71-82
[8]  
JOHNKE T, 2002, SIEMENS POWER J MAY
[9]   Humidified gas turbines - a review of proposed and implemented cycles [J].
Jonsson, M ;
Yan, JY .
ENERGY, 2005, 30 (07) :1013-1078
[10]   Compressor intake-air cooling in gas turbine plants [J].
Kakaras, E ;
Doukelis, A ;
Karellas, S .