Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices

被引:127
作者
Spanier, T
Oz, M
Levin, H
Weinberg, A
Stamatis, K
Stern, D
Rose, E
Schmidt, AM
机构
[1] COLUMBIA UNIV COLL PHYS & SURG,DEPT MED,NEW YORK,NY 10032
[2] COLUMBIA UNIV COLL PHYS & SURG,DEPT BIOSTAT,NEW YORK,NY 10032
[3] COLUMBIA UNIV COLL PHYS & SURG,DEPT PHYSIOL,NEW YORK,NY 10032
关键词
D O I
10.1016/S0022-5223(96)70111-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left ventricular assist devices have provided successful supportive therapy for patients awaiting cardiac transplantation for extended periods of time. Although thromboembolic events have complicated support with these de vices, the: HeartMate left ventricular assist device developed by Thermo Cardiosystems, Inc., Woburn, Massachusetts, was specifically designed with a textured blood-contacting surface to minimize this risk. Clinical experience with this de,ice has been encouraging, inasmuch as minimal thromboembolic complications have occurred despite the absence of anticoagulation, The coagulation and fibrinolytic pathways in these individuals were investigated to better understand the hematologic status of patients treated with the Thermo Cardiosystems device. Despite apparently normal prothrombin and activated partial thromboplastin times, as well as platelet counts, evidence of significant thrombin generation and fibrinolysis was present, To eliminate underlying cardiac failure as the responsible factor for these abnormalities, we made similar measurements in patients with end-stage heart failure who were not supported by an assist device or anticoagulation. These measurements revealed no evidence of thrombin generation or fibrinolysis. These data demonstrate that patients supported with a left ventricular assist device, while successfully sustained without systemic anticoagulation, nevertheless have evidence of activation of coagulation, These phenomena appear to be related to the presence of the device rather than to the underlying: cardiac abnormalities, Although procoagulant and fibrinolytic pathways are apparently balanced in these patients, these data underscore the potential for the development of bleeding or thrombosis in clinically relevant settings.
引用
收藏
页码:1090 / 1097
页数:8
相关论文
共 30 条
[1]  
BAUER KA, 1988, BLOOD, V71, P1418
[2]   AN IMPROVED BLOOD-PUMP INTERFACE FOR LEFT-VENTRICULAR BYPASS [J].
BERNHARD, WF ;
LAFARGE, CG ;
ROBINSON, T ;
YUN, I ;
SHIRAHIGE, K ;
KITRILAKIS, S .
ANNALS OF SURGERY, 1968, 168 (04) :750-+
[3]   NEW PRINCIPLES GOVERNING TISSUE REACTIVITY OF PROSTHETIC MATERIALS [J].
CLARK, RE ;
BOYD, JC ;
MORAN, JF .
JOURNAL OF SURGICAL RESEARCH, 1974, 16 (05) :510-522
[4]  
Conover W. J., 1980, Practical nonparametric statistics, V2nd
[5]  
DASSE KA, 1987, T AM SOC ART INT ORG, V33, P418
[6]  
DIDISHEIM P, 1987, T AM SOC ART INT ORG, V33, P418
[7]   THE POTENTIAL SUPPLY OF ORGAN DONORS - AN ASSESSMENT OF THE EFFICIENCY OF ORGAN PROCUREMENT EFFORTS IN THE UNITED-STATES [J].
EVANS, RW ;
ORIANS, CE ;
ASCHER, NL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (02) :239-246
[8]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[9]  
FRAZIER OH, 1993, TEX HEART I J, V20, P78
[10]   NEOINTIMAL DEVELOPMENT ON TEXTURED BIOMATERIAL SURFACES DURING CLINICAL USE OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE [J].
GRAHAM, TR ;
DASSE, K ;
COUMBE, A ;
SALIH, V ;
MARRINAN, MT ;
FRAZIER, OH ;
LEWIS, CT .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1990, 4 (04) :182-190