Comparison of continuous left ventricular volumes by transthoracic two-dimensional digital echo quantification with simultaneous conductance catheter measurements in patients with cardiac diseases

被引:29
作者
Chen, CH [1 ]
Nevo, E [1 ]
Fetics, B [1 ]
Nakayama, M [1 ]
Pak, PH [1 ]
Maughan, WL [1 ]
Kass, DA [1 ]
机构
[1] JOHNS HOPKINS UNIV, INST MED, DEPT INTERNAL MED, DIV CARDIOL, BALTIMORE, MD USA
关键词
D O I
10.1016/S0002-9149(97)00509-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automated border detection enables real-time tracking of left ventricular (LV) volume by 2-dimensional transthoracic echocardiography. This technique has not been previously compared with simultaneously measured continuous LV volumes at rest or during transients in humans. We performed 18 studies in 16 patients (age 50 +/- 15 years, range 22 to 70; ejection fraction 63 +/- 20%, range 15% to 85%) in which continuous LV volumes acquired by digital echo quantification (DEQ) were compared with simultaneous conductance catheter volume obtained by cardiac catheterization. Both volume signals were calibrated by thermodilution-derived cardiac output and ventriculogram-derived election fraction. Volume traces acquired at rest were averaged to generate a comparison cycle. The averaged volume waveforms acquired by DEQ and by conductance catheter were similar during all phases of the cardiac cycle and significantly correlated (conductance catheter = slope . DEQ + intercept, slope = 0.94 +/- 0.09, intercept = 5 +/- 8 ml, r(2) = 0.86 +/- 0.12, all p <0.0001). Steady-state hemodynamic parameters calculated using either averaged volume signal were significantly correlated. Transient obstruction of the inferior vena cava yielded a 45 +/- 13% decrease in end-diastolic volume. Successful recordings of DEQ volume during preload reduction were obtained; in only 50% of studies. End-diastolic volumes from the 2 methods were significantly correlated (mean slope 0.88 +/- 0.31, mean intercept 14 +/- 37 ml, average r(2) = 0.89 +/- 0.11, all p <0.01), as were end-systolic volumes: mean slope 0.80 +/- 0.43, intercept = -20 +/- 26 ml, r(2) 0.67 +/- 0.18, all p <0.05). We conclude that automated border detection technique by DEQ is reliable for noninvasive, transthoracic, continuous tracking of LV volumes at steady state, but has limitations in use during preload reduction maneuvers in humans. (C) 1997 by Excerpta Medica, Inc.
引用
收藏
页码:756 / 761
页数:6
相关论文
共 27 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
CHENZBRAUN A, 1993, BRIT HEART J, V70, P448
[3]   FILLING PATTERNS IN LEFT-VENTRICULAR HYPERTROPHY - A COMBINED ACOUSTIC QUANTIFICATION AND DOPPLER STUDY [J].
CHENZBRAUN, A ;
PINTO, FJ ;
POPYLISEN, S ;
SCHNITTGER, I ;
POPP, RL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) :1179-1185
[4]   Acute cardiovascular effects of OPC-18790 in patients with congestive heart failure - Time- and dose-dependence analysis based on pressure-volume relations [J].
Feldman, MD ;
Pak, PH ;
Wu, CC ;
Haber, HL ;
Heesch, CM ;
Bergin, JD ;
Powers, ER ;
Cowart, TD ;
Johnson, W ;
Feldman, AM ;
Kass, DA .
CIRCULATION, 1996, 93 (03) :474-483
[5]   LINEARITY OF THE FRANK-STARLING RELATIONSHIP IN THE INTACT HEART - THE CONCEPT OF PRELOAD RECRUITABLE STROKE WORK [J].
GLOWER, DD ;
SPRATT, JA ;
SNOW, ND ;
KABAS, JS ;
DAVIS, JW ;
OLSEN, CO ;
TYSON, GS ;
SABISTON, DC ;
RANKIN, JS .
CIRCULATION, 1985, 71 (05) :994-1009
[6]   ASSESSMENT OF LEFT-VENTRICULAR PERFORMANCE BY ONLINE PRESSURE-AREA RELATIONS USING ECHOCARDIOGRAPHIC AUTOMATED BORDER DETECTION [J].
GORCSAN, J ;
ROMAND, JA ;
MANDARINO, WA ;
DENEAULT, LG ;
PINSKY, MR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (01) :242-252
[7]   ONLINE ESTIMATION OF CHANGES IN LEFT-VENTRICULAR STROKE VOLUME BY TRANSESOPHAGEAL ECHOCARDIOGRAPHIC AUTOMATED BORDER DETECTION IN PATIENTS UNDERGOING CORONARY-ARTERY BYPASS-GRAFTING [J].
GORCSAN, J ;
GASIOR, TA ;
MANDARINO, WA ;
DENEAULT, LG ;
HATTLER, BG ;
PINSKY, MR .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (09) :721-727
[8]   COMPARISON OF LEFT-VENTRICULAR FUNCTION BY ECHOCARDIOGRAPHIC AUTOMATED BORDER DETECTION AND BY RADIONUCLIDE EJECTION FRACTION [J].
GORCSAN, J ;
LAZAR, JM ;
SCHULMAN, DS ;
FOLLANSBEE, WP .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (11) :810-815
[9]   ONLINE ESTIMATION OF STROKE VOLUME BY MEANS OF ECHOCARDIOGRAPHIC AUTOMATED BORDER DETECTION IN THE CANINE LEFT-VENTRICLE [J].
GORCSAN, J ;
LAZAR, JM ;
ROMAND, J ;
PINSKY, MR .
AMERICAN HEART JOURNAL, 1993, 125 (05) :1316-1323
[10]  
Gorcsan J 3rd, 1993, J Am Soc Echocardiogr, V6, P482