Why are total knee arthroplasties failing today?

被引:932
作者
Sharkey, PF
Hozack, WJ
Rothman, RH
Shastri, S
Jacoby, SM
机构
[1] Rothman Inst, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ Hosp, Philadelphia, PA 19107 USA
[3] Thomas Jefferson Univ, Jefferson Med Coll, Philadelphia, PA 19107 USA
关键词
D O I
10.1097/01.blo.0000036002.13841.32
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The incidence of failure after knee replacement is low, yet it has been reported that more than 22,000 knee replacements are revised yearly. The purpose of the current study was to determine current mechanisms of failure of total knee arthroplastics. A retrospective review was done on all patients who had revision total knee arthroplasty during a 3-year period (September 1997-October 2000) at one institution. The preoperative evaluation in conjunction with radiographs, laboratory data, and intraoperative findings were used to determine causes of failure. Two hundred twelve surgeries were done on 203 patients (nine patients had bilateral surgeries). The reasons for failure listed in order of prevalence among the patients in this study include polyethylene wear, aseptic loosening, instability, infection, arthrofibrosis, malalignment or malposition, deficient extensor mechanism, avascular necrosis in the patella, periprosthetic fracture, and isolated patellar resurfacing. The cases reviewed included patients who had revision surgery within 9 days to 28 years (average, 3.7 years) after the previous surgery. More than half of the revisions in this group of patients were done less than 2 years after the index operation. Fifty percent of early revision total knee arthroplasties in this series were related to instability, malalignment or malposition, and failure of fixation.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 28 条
[1]
Fracture of the metal tibial tray after kinematic total knee replacement - A common cause of early aseptic failure [J].
Abernethy, PJ ;
Robinson, CM ;
Fowler, RM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :220-225
[2]
Early failure associated with the use of Hylamer-M spacers in three primary AMK total knee arthroplasties [J].
Ahn, NU ;
Nallamshetty, L ;
Ahn, UM ;
Buchowski, JM ;
Rose, PS ;
Lemma, MA ;
Wenz, JF .
JOURNAL OF ARTHROPLASTY, 2001, 16 (01) :136-139
[3]
Patellar resurfacing in total knee arthroplasty - A prospective, randomized, double-blind study with five to seven years of follow-up [J].
Barrack, RL ;
Bertot, AJ ;
Wolfe, MW ;
Waldman, DA ;
Milicic, M ;
Myers, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (09) :1376-1381
[4]
BEIGHT JL, 1994, CLIN ORTHOP RELAT R, P139
[5]
BLISS DG, 1985, CLIN ORTHOP RELAT R, P207
[6]
CAMERON HU, 1982, CLIN ORTHOP RELAT R, P141
[7]
Chan W. H., 1998, SMJ, V39, P303
[8]
THE POSTERIOR STABILIZED TOTAL KNEE PROSTHESIS - ASSESSMENT OF POLYETHYLENE DAMAGE AND OSTEOLYSIS AFTER A 10-YEAR-MINIMUM FOLLOW-UP [J].
COLIZZA, WA ;
INSALL, JN ;
SCUDERI, GR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) :1713-1720
[9]
Prophylactic use of antibiotics for procedures after total joint replacement [J].
Deacon, JM ;
Pagliaro, AJ ;
Zelicof, SB ;
Horowitz, HW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (11) :1755-1770
[10]
Survivorship analysis of the kinematic stabilizer total knee replacement - A 10- to 14-year follow-up [J].
Emmerson, KP ;
Moran, CG ;
Pinder, IM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :441-445