1-butanol removal from a contaminated airstream under continuous and diurnal loading conditions

被引:31
作者
Fitch, MW
England, E
Zhang, B
机构
[1] Univ Missouri, Dept Civil Engn, Rolla, MO 65409 USA
[2] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 2002年 / 52卷 / 11期
关键词
D O I
10.1080/10473289.2002.10470866
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A polysulfone microporous membrane module was investigated for control of 1-butanol-contaminated gas streams. A diurnal loading condition, using two different butanol concentrations, was used to simulate start-up and stop conditions associated with shift work. The membrane module was also used to remove 1-butanol from air. under continuous loading conditions in a bioreactor. The reactors were seeded with a mixed bacterial consortium capable of butanol biodegradation. Bickinetic parameters for butanol utilization were determined for the culture to be a maximum specific utilization rate (k) equal to 4.3 d(-1) and a half saturation constant (K-s) equal to 8.9 mg L-1. A biofilter running only with diurnal loading conditions giving a "40-hr workweek" had an average 1-butanol removal rate of 29% (111 ppm, 74 gm(-3) hr(-1)) from a 350-ppm influent at the end of an 8-hr operational day. End-of-day removal varied between 4 and 67% during the operational period. With continuous steady-state operation followed by placement on a diurnal loading schedule and influent butanol concentrations increased to 700 ppm, butanol removal averaged 38% (269 ppm, 145 gm(-3) hr(-1)). Under continuous loading, steady-state conditions, 1-butanol removal from the airstream was greater than 99% (200 ppm, 73 gm(-3) hr(-1)). These results suggest that the bioreactor can be operated on a diurnal schedule or 40-hr week operational schedule without any decline in performance.
引用
收藏
页码:1288 / 1297
页数:10
相关论文
共 27 条
[1]  
[Anonymous], 2000, ELEMENTS ECOLOGY
[2]  
*APHA AM WAT WORKS, 1995, STAND METH EX WAT WA
[3]   METHANOTROPHIC BIODEGRADATION OF TRICHLOROETHYLENE IN A HOLLOW-FIBER MEMBRANE BIOREACTOR [J].
AZIZ, CE ;
FITCH, MW ;
LINQUIST, LK ;
PRESSMAN, JG ;
GEORGIOU, G ;
SPEITEL, GE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (10) :2574-2583
[4]   Modeling biofiltration of VOC mixtures under steady-state conditions [J].
Baltzis, BC ;
Wojdyla, SM ;
Zarook, SM .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 1997, 123 (06) :599-605
[5]  
CUNHA LM, 1994, BINARY-COMPUT MICROB, V6, P167
[6]  
Devinny JS., 1999, BIOFILTRATION AIR PO
[7]   DICHLOROETHANE REMOVAL FROM GAS STREAMS BY AN EXTRACTIVE MEMBRANE BIOREACTOR [J].
DOSSANTOS, LMF ;
HOMMERICH, U ;
LIVINGSTON, AG .
BIOTECHNOLOGY PROGRESS, 1995, 11 (02) :194-201
[8]  
Ergas SJ, 1999, BIOTECHNOL BIOENG, V63, P431, DOI 10.1002/(SICI)1097-0290(19990520)63:4<431::AID-BIT6>3.0.CO
[9]  
2-G
[10]   Membrane bioreactor for control of volatile organic compound emissions [J].
Ergas, SJ ;
McGrath, MS .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1997, 123 (06) :593-598