A comparison of manual and controlled-force attachment-level measurements

被引:28
作者
Reddy, MS
Palcanis, KG
Geurs, NC
机构
[1] University of Alabama at Birmingham, Department of Periodontics, UAB Station 34, Birmingham
关键词
periodontal probing; attachment level measurement; periodontal probe;
D O I
10.1111/j.1600-051X.1997.tb01212.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared the intra-examiner and inter-examiner error of 2 constant force probes to the reading of a conventional manual probe. 3 examiners made repeated examinations of attachment level using a modified Florida probe and a manual North Carolina probe (read to 1 mm or 0.5 mm); relative attachment level measurements were made using a Florida disk probe. One probe was used in each quadrant in 8 subjects with moderate to advanced periodontitis. Error was calculated as the mean of the absolute value of the difference between each examination, and the correlation between values at each examination calculated. Statistically-significant differences between probe type, examiners, and sites were detected using a repeated measures ANOVA accounting for the nesting within subjects. There was a significant difference in error by probe type (modified Florida probe 0.62 +/- 0.03 mm, r = 0.86; Florida stent probe 0.55 +/- 0.05 mm, r = 0.82; manual probe to 1 mm 0.39 +/- 0.02 mm, r = 0.88; manual probe to 0.5 mm 0.40 +/- 0.02 mm, r = 0.89; (p < 0.001). Significant differences were observed by examiners (p < 0.01). These data indicate that both manual and controlled-force probes can provide measurement within less than 1 mm of error; however, individual calibration of examiners remains important in the reduction of error.
引用
收藏
页码:920 / 926
页数:7
相关论文
共 24 条
[1]   REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS [J].
BADERSTEN, A ;
NILVEUS, R ;
EGELBERG, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) :475-485
[2]   EVALUATION OF PERIODONTAL PROBING FORCES [J].
FREED, HK ;
GAPPER, RL ;
KALKWARF, KL .
JOURNAL OF PERIODONTOLOGY, 1983, 54 (08) :488-492
[3]  
Galgut P N, 1990, Int Dent J, V40, P333
[4]   GINGIVAL RESISTANCE TO PROBING FORCES .2. THE EFFECT OF INFLAMMATION AND PRESSURE ON PROBE DISPLACEMENT IN BEAGLE DOG GINGIVITIS [J].
GARNICK, JJ ;
KEAGLE, JG ;
SEARLE, JR ;
KING, GE ;
THOMPSON, WO .
JOURNAL OF PERIODONTOLOGY, 1989, 60 (09) :498-505
[5]   AN ASSESSMENT OF THE VALIDITY OF A CONSTANT FORCE ELECTRONIC PROBE IN MEASURING PROBING DEPTHS [J].
HULL, PS ;
CLEREHUGH, V ;
GHASSEMIAVAL, A .
JOURNAL OF PERIODONTOLOGY, 1995, 66 (10) :848-851
[6]   NON-GAUSSIAN DISTRIBUTION OF DIFFERENCES BETWEEN DUPLICATE PROBING DEPTH MEASUREMENTS [J].
JANSSEN, PTM ;
FABER, JAJ ;
HELDERMAN, WHV .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1987, 14 (06) :345-349
[7]   EFFECT OF PROBING DEPTH AND BLEEDING TENDENCY ON THE REPRODUCIBILITY OF PROBING DEPTH MEASUREMENTS [J].
JANSSEN, PTM ;
FABER, JAJ ;
HELDERMAN, WHV .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (09) :565-568
[8]   ERRORS IN MEASURING PARAMETERS ASSOCIATED WITH PERIODONTAL HEALTH AND DISEASE [J].
KINGMAN, A ;
LOE, H ;
ANERUD, A ;
BOYSEN, H .
JOURNAL OF PERIODONTOLOGY, 1991, 62 (08) :477-486
[9]   PERIODONTAL PROBING - WHAT DOES IT MEAN [J].
LISTGARTEN, MA .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1980, 7 (03) :165-176
[10]   CORRELATION BETWEEN ELECTRONIC AND VISUAL READINGS OF POCKET DEPTHS WITH A NEWLY DEVELOPED CONSTANT FORCE PROBE [J].
MAGNUSSON, I ;
FULLER, WW ;
HEINS, PJ ;
RAU, CF ;
GIBBS, CH ;
MARKS, RG ;
CLARK, WB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) :180-184