Arthroscopic collagen meniscus implant results at 6 to 8 years follow up

被引:112
作者
Zaffagnini, Stefano [1 ]
Giordano, Giovanni [1 ]
Vascellari, Alberto [1 ]
Bruni, Danilo [1 ]
Neri, Maria Pia [1 ]
Iacono, Francesco [1 ]
Kon, Elizaveta [1 ]
Lo Presti, Mirco [1 ]
Marcacci, Maurilio [1 ]
机构
[1] Rizzoli Orthopaed Inst, Biomech Dept, I-40136 Bologna, Italy
关键词
meniscus; collagen; arthroscopic; implant; DJD (degenerative joint disease);
D O I
10.1007/s00167-006-0144-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Meniscal substitution is a fundamental procedure to prevent osteoarthritis of the knee after massive meniscectomy. Stone, Steadman and Rodkey have developed a bioreadsorbable collagen matrix (CMI) which acts as a scaffold to restore the original medial meniscal. The objective of this study was to prospectively evaluate the results of CMI implantation at a follow up from a minimum of 6 to a maximum of 8 years. Eight patients (mean age 25) were evaluated at a final observation point from 6 to 8 years after CMI implantation. Inclusion criteria were an irreparable meniscal tear or a previous meniscectomy involving the medial meniscus. Follow up evaluation included Cincinnati Knee Rating Scale (CKRS), IKDC, subjective evaluation and X-ray and MRI control. There were no complications related to the device. All patients were able to return to day activities without limitations 3 months after surgery. Both subjective CKRS score and objective IKDC score showed improvement in all cases except one patient with an ACL re-injury. In two cases scores were slightly worse from 2 years after surgery to the final observation point. The other five cases obtained maximum score at final follow-up. In four cases the absence of pain remained until the final observation point, while in four cases a low entity of pain was described at long term follow-up. MRI showed in five cases mixoid degeneration signal, two had normal signal with reduced size, while one patient had no recognizable implant. Six patients had preserved cartilage and articular space, with no changes respect to pre-op control. Arthroscopic second look evaluation has been performed in three cases, revealing in two cases the presence of the implant, although with a reduced size respect to the original one, while in one case the CMI was almost disappeared. Our small series of eight patients prospectively followed from 6 to 8 years of follow-up has shown highly satisfactory results. Although the aspect of the implant was mostly abnormal, the implant may have helped reduce the deterioration of the knee joint at final observation time.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 50 条
[1]
Arnoczky SP, 1992, KNEE MENISCUS BASIC, P1
[2]
Arnoczky SP, 1988, INJURY REPAIR MUSCUL, P487
[3]
Benedetto K P, 1993, Knee Surg Sports Traumatol Arthrosc, V1, P235, DOI 10.1007/BF01560216
[4]
ISOLATED ARTHROSCOPIC PARTIAL MENISCECTOMY - FUNCTIONAL RADIOGRAPHIC EVALUATION AT 5 YEARS [J].
BOLANO, LE ;
GRANA, WA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (03) :432-437
[5]
Bullough P G, 1970, J Bone Joint Surg Br, V52, P564
[6]
BURKE VJ, 1997, US IALE NEWSLETTER, V13, P6
[7]
BURR DB, 1982, CLIN ORTHOP RELAT R, P121
[8]
CARTER TR, 1995, 9 ANN M MEN ALL STUD
[9]
A comparative study of medial versus lateral arthroscopic partial meniscectomy on stable knees: 10-year minimum follow-up [J].
Chatain, F ;
Adeleine, P ;
Chambat, P ;
Neyret, P .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (08) :842-849
[10]
KNEE JOINT CHANGES AFTER MENISCECTOMY [J].
FAIRBANK, TJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1948, 30 (04) :664-670