Morphometry and strain distribution of the C57BL/6 mouse aorta

被引:44
作者
Guo, X
Kono, Y
Mattrey, R
Kassab, GS
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2002年 / 283卷 / 05期
关键词
opening angle; zero-stress state; ultrasound; diameter; stress;
D O I
10.1152/ajpheart.00224.2002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The goal of the present study was to obtain a systematic set of data along the length of the mouse aorta to study variations of morphometry (diameter, wall thickness, and curvature), strain, and stress of the mouse aorta. Five mice were imaged with a 13-MHz ultrasound probe to determine the in vivo diameter along the aorta. A cast was made of these aortas to validate the ultrasonic diameter measurements. The root mean squared and systematic errors for these measurements were 12.6% and 6.4% of the mean ultrasound diameter, respectively. The longitudinal variations of geometry, stress, and strain from the aortic valve to the common iliac bifurcation were documented. Our results show that the residual circumferential strain leads to a uniformity of transmural strain of the aorta in the loaded state along the entire length of the aorta. Furthermore, we validated the incompressibility condition along the length of the aorta. These data of normal mice will serve as a reference state for the study of disease in future knockout models.
引用
收藏
页码:H1829 / H1837
页数:9
相关论文
共 32 条
[1]   COMPRESSIBILITY OF ARTERIAL WALL [J].
CAREW, TE ;
VAISHNAV, RN ;
PATEL, DJ .
CIRCULATION RESEARCH, 1968, 23 (01) :61-&
[2]   Transrectal ultrasound assessment of murine aorta and iliac arteries [J].
Chiou, AC ;
Chiu, B ;
Oppat, WF ;
Matsumura, JS ;
Chisholm, RL ;
Pearce, WH .
JOURNAL OF SURGICAL RESEARCH, 2000, 88 (02) :193-199
[3]  
Chuong C.-J., 1986, FRONTIERS BIOMECHANI
[4]   3-DIMENSIONAL STRESS-DISTRIBUTION IN ARTERIES [J].
CHUONG, CJ ;
FUNG, YC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :268-274
[5]   COMPRESSIBILITY AND CONSTITUTIVE EQUATION OF ARTERIAL-WALL IN RADIAL COMPRESSION EXPERIMENTS [J].
CHUONG, CJ ;
FUNG, YC .
JOURNAL OF BIOMECHANICS, 1984, 17 (01) :35-40
[6]  
Dunn T., 1965, PATHOLOGY LABORATORY, P303
[7]  
Faraci FM, 1999, CIRC RES, V85, P1214
[8]  
FESTING M F W, 1971, Laboratory Animals (London), V5, P179, DOI 10.1258/002367771781006564
[9]  
FUNG Y. C., 1965, Foundations of solid mechanics
[10]   STRAIN DISTRIBUTION IN SMALL BLOOD-VESSELS WITH ZERO-STRESS STATE TAKEN INTO CONSIDERATION [J].
FUNG, YC ;
LIU, SQ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (02) :H544-H552