Visual integration of data and basic motor skills under laparoscopy - Influence of 2-D and 3-D video-camera systems

被引:62
作者
Dion, YM
Gaillard, F
机构
[1] Department of Surgery, St.-François d'Assise Hosp., Québec City, Que. G1L 3L5
[2] Laval University, Québec City, Que.
[3] Quebec Biomaterials Institute, Québec City, Que.
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 1997年 / 11卷 / 10期
关键词
laparoscopy; in vitro tests; three-dimensional videocamera system; monocularity; binocularity;
D O I
10.1007/s004649900510
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The qualities of visual perception and of motor reaction to the visual stimulus have never been studied in reference to the type of video-camera system (2-D vs 3-D) used during laparoscopy. Methods: The study was designed in two parts. The first evaluated the ability of the eye to discriminate how objects are spaced relative to one another. The second investigated the motor reaction to the visual stimulus in an environment where depth was the preponderent cue. The tests were per formed in a pelvi-trainer in which were inserted different modules built either for visual observation (Part 1) or for evaluation of motor ability (Part 2). Variables studied dur ing Part 1 were the time required to do the test and the number of errors committed during its performance. The variable evaluated during Part 2 was the time needed to terminate the test, Each of these two parts of the study were completed alternating the 2-D and 3-D systems. A total of 304 observations were recorded. Statistics used were the paired t-test, the independent group t-test, and the Newman-Keuls multiple comparisons test. Results: Results of Part 1 of the study confirm that visual perception varies significantly among individuals (n = 10) (p < 0.05) and that a true 3-D video-camera system facilitates visual perception when compared to a 2-D system (p < 0.001). Results of Part 2 of the study also show significant differences among participants (n = 9) (p < 0.05). The true 3-D system allowed significantly faster motor performances than the 2-D system (p < 0.001). Conclusion: Our experiment shows that the 3-D system allowed significant improvements in the execution of the evaluated parameters. Also noted were significant differences among participants in term of visual and motor skills.
引用
收藏
页码:995 / 1000
页数:6
相关论文
共 25 条
[1]   3-D IMAGING IN GASTROINTESTINAL LAPAROSCOPY [J].
BIRKETT, DH .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1993, 7 (06) :556-557
[2]  
BIRKETT DH, 1994, SURG ENDOSC-ULTRAS, V8, P1448
[3]  
BIRKETT DH, 1994, INT SURG, V79, P357
[4]   FURTHER DEVELOPMENTS IN BINOCULAR SUMMATION [J].
BLAKE, R ;
SLOANE, M ;
FOX, R .
PERCEPTION & PSYCHOPHYSICS, 1981, 30 (03) :266-276
[5]  
BLAKE R, 1977, EXP BRAIN RES, P221
[6]  
BLAKE R, 1981, PERCEPT PSYCHOPHYS, P161
[7]  
BOECKMANN W, 1995, MINIMALLY INVASIV S1, V4, P39
[8]   BINOCULAR ENHANCEMENT OF VISUAL-ACUITY [J].
CAGENELLO, R ;
ARDITI, A ;
HALPERN, DL .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (08) :1841-1848
[9]   MONOCULAR VERSUS BINOCULAR VISUAL ACUITY [J].
CAMPBELL, FW ;
GREEN, DG .
NATURE, 1965, 208 (5006) :191-&
[10]  
CRUZ AAV, 1989, BRAZ J MED BIOL RES, V22, P1355