Bradyarrhythmias during use of the AngioJet system

被引:50
作者
Dwarka, Dan [1 ]
Schwartz, Stephanie A. [1 ]
Smyth, Stephen H. [1 ]
O'Brien, Michael J. [1 ]
机构
[1] Univ Arizona, Hlth Sci Ctr, Dept Radiol, Tucson, AZ 85724 USA
关键词
D O I
10.1097/01.RVI.0000236629.26319.65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The AngioJet system is an effective thrombectomy device, but it may cause chest discomfort and provoke bradyarrhythmias that range from mild bradycardia to asystole. The cause of AngioJet-induced bradyarrhythmia is unknown, although several hypotheses have attempted to explain the phenomenon. Herein several cases will be described, followed by a review of the relevant literature. The literature review suggests that the cause may be related to the effects of the hydrodynamic jets on stretch-activated receptors present on the vascular endothelium, and that pretreatment with gadolinium or streptomycin might prevent activation of these receptors.
引用
收藏
页码:1693 / 1695
页数:3
相关论文
共 13 条
[1]   Thrombectomy for acute internal carotid thrombosis: Five thrombectomy devices compared [J].
Chant, H ;
Ashleigh, R ;
McCollum, C .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (04) :403-408
[2]   Modification of stretch-induced shortening of repolarization by streptomycin in the isolated rabbit heart [J].
Eckardt, L ;
Kirchhof, P ;
Mönnig, G ;
Breithardt, G ;
Borggrefe, M ;
Haverkamp, W .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 2000, 36 (06) :711-721
[3]   Type III heart block with peripheral use of the AngioJet thrombectomy system [J].
Fontaine, AB ;
Borsa, JJ ;
Hoffer, EK ;
Bloch, RD ;
So, CR ;
Newton, M .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (10) :1223-1225
[4]   Submassive pulmonary embolism and paradoxical embolic stroke treated with percutaneous rheolytic thrombectomy and closure of the patent foramen ovale [J].
Iskander, A ;
Nayak, A ;
Chauhan, MS .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 64 (03) :356-360
[5]   Mechanoelectrical excitation by fluid jets in monolayers of cultured cardiac myocytes [J].
Kong, CR ;
Bursac, N ;
Tung, L .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (06) :2328-2336
[6]  
Lee Michael S, 2005, J Invasive Cardiol, V17, P19
[7]  
Lee Michael S, 2004, J Invasive Cardiol, V16, P587
[8]   In vitro effectiveness of mechanical thrombectomy devices for large vessel diameter and low-pressure fluid dynamic applications [J].
Müller-Hülsbeck, S ;
Grimm, J ;
Leidt, J ;
Heller, M .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (08) :831-839
[9]   Rheolytic thrombectomy with use of the AngioJet-F1O5 catheter: Preclinical evaluation of safety [J].
Sharafuddin, MJA ;
Hicks, ME ;
Jenson, ML ;
Morris, JE ;
Drasler, WJ ;
Wilson, GJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (06) :939-945
[10]   Effect of gadolinium on stretch-induced changes in contraction and intracellularly recorded action- and afterpotentials of rat isolated atrium [J].
Tavi, P ;
Laine, M ;
Weckstrom, M .
BRITISH JOURNAL OF PHARMACOLOGY, 1996, 118 (02) :407-413