A finite element analysis for predicting outcomes of cemented total knee arthroplasty

被引:9
作者
Gheorghiu, Nicolae [1 ,2 ]
Socea, Bogdan [3 ,4 ]
Dimitriu, Mihai C. T. [5 ,6 ]
Bacalbasa, Nicolae [5 ,7 ]
Stan, Gabriel [1 ,2 ]
Orban, Horia [1 ,2 ]
机构
[1] Carol Davila Univ Med & Pharm, Dept Orthoped, Bucharest 020021, Romania
[2] Elias Emergency Clin Hosp, Dept Orthoped, Bucharest 011416, Romania
[3] Carol Davila Univ Med & Pharm, Dept Surg, 37 Dionisie Lupu St, Bucharest 020021, Romania
[4] Sf Pantelimon Emergency Hosp, Dept Surg, Bucharest 021659, Romania
[5] Carol Davila Univ Med & Pharm, Dept Obstet & Gynecol, Bucharest 020021, Romania
[6] Sf Pantelimon Emergency Hosp, Dept Obstet & Gynecol, Bucharest 021659, Romania
[7] Dr I Cantacuzino Clin Hosp, Dept Obstet & Gynecol, Bucharest 020475, Romania
关键词
biomedical computing; polyethylene stress; clinical trials; orthopedic procedures; surgery;
D O I
10.3892/etm.2021.9698
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
100103 [病原生物学]; 100218 [急诊医学];
摘要
The study was designed to assess the validity of a finite element analysis for predicting the behavior of cemented knee implant used in total knee arthroplasty (TKA), for different mechanical loads, and correlation with clinical outcomes of this procedure. We conducted computational simulations using finite element analysis of two situations: i) The ideal prosthetic component positioning; and ii) variable varus tibial malposition, but with a balanced knee. A total of 80 cemented TKAs performed on 70 patients were divided into two groups. Patients from one group required secondary asymmetric tibial recut for balancing the prosthetic knee and patients from the other group, did not. In regards to the results, we observed no differences upon analysis of the postoperative results of the Knee Society Score (KSS), the angle between the femur and tibia, the range of motion and frontal laxity between groups. The finite element analysis showed that in a 3 varus inclination of the joint interline, but with a balanced knee, the maximum contact stress, measured on the tibial plateau surface, increased by 11% compared to the value of mechanical alignment. In conclusion, analysis of the computational model using finite elements showed predictable results of cemented TKA for the different situations of mechanical loads.
引用
收藏
页数:5
相关论文
共 20 条
[1]
Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[2]
Biological response to prosthetic debris [J].
Bitar, Diana ;
Parvizi, Javad .
WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (02) :172-189
[3]
Kinematically Versus Mechanically Aligned Total Knee Arthroplasty [J].
Dossett, H. Gene ;
Swartz, George J. ;
Estrada, Nicolette A. ;
LeFevre, George W. ;
Kwasman, Bertram G. .
ORTHOPEDICS, 2012, 35 (02) :E160-E169
[4]
Coronal Alignment in Total Knee Arthroplasty Just How Important is it? [J].
Fang, David M. ;
Ritter, Merrill A. ;
Davis, Kenneth E. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :39-43
[5]
How Frequently Do Four Methods for Mechanically Aligning a Total Knee Arthroplasty Cause Collateral Ligament Imbalance and Change Alignment from Normal in White Patients? AAOS Exhibit Selection [J].
Gu, Yu ;
Roth, Joshua D. ;
Howell, Stephen M. ;
Hull, Maury L. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (12) :e101(1)
[6]
Howell S M., 2014, Arthropaedia, V1, P44, DOI DOI 10.1016/B978-1-4377-1503-3.00120-7
[7]
Howell SM, 2012, KINEMATIC ALIGNMENT
[8]
HSU RWW, 1990, CLIN ORTHOP RELAT R, P215
[9]
Influence of post-cam design on stresses on posterior-stabilized tibial posts [J].
Huang, Chang-Hung ;
Liau, Jiann-Jong ;
Huang, Chun-Hsiung ;
Cheng, Cheng-Kung .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (450) :150-156
[10]
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13