Intracapsular implant rupture: MR findings of incomplete shell collapse

被引:29
作者
Soo, MS
Kornguth, PJ
Walsh, R
Elenberger, C
Georgiade, GS
DeLong, D
Spritzer, CE
机构
[1] Department of Radiology, Duke University Medical Center, Durham
[2] Department of Surgery, Duke University Medical Center, Durham
[3] Florida Radiology Associates, P.A., Altamonte Springs
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 04期
关键词
breast; MR; prostheses;
D O I
10.1002/jmri.1880070419
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to determine the frequency and significance of the MR findings of incomplete shell collapse for detecting implant rupture in a series of surgically removed breast prostheses, MR images of 86 breast implants in 44 patients were studied retrospectively and correlated with surgical findings at explantation. MR findings Included (a) complete shell collapse (linguine sign], 21 implants; (b) incomplete shell collapse (subcapsular line sign, teardrop sign, and keyhole sign), 33 implants; [c) radial folds, 31 implants; and (d) normal, 1 implant, The subcapsular line sign was seen in 26 implants, the teardrop sign was seen in 27 implants, and the keyhole sign was seen in 23 implants, At surgery, 48 implants were found to be ruptured and 38 were intact. The MR findings of ruptured implants showed signs of incomplete collapse in 52% (n = 25), linguine sign in 44% (n = 21), and radial folds in 4% (n = 2). The linguine sign perfectly predicted implant rupture, but sensitivity was low. Findings of incomplete shell collapse improved sensitivity and negative predictive values, and the subcapsular line sign produced a significant incremental increase in predictive ability, MRI signs of incomplete shell collapse were more common than the linguine sign in ruptured implants and are significant contributors to the high sensitivity and negative predictive values of MRI for evaluating implant integrity.
引用
收藏
页码:724 / 730
页数:7
相关论文
共 13 条
[1]   DEFINITIVE DIAGNOSIS OF BREAST IMPLANT RUPTURE USING MAGNETIC-RESONANCE-IMAGING [J].
AHN, CY ;
SHAW, WW ;
NARAYANAN, K ;
GORCZYCA, DP ;
SINHA, S ;
DEBRUHL, ND ;
BASSETT, LW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (04) :681-691
[2]   MR-IMAGING OF THE BREAST IN PATIENTS WITH SILICONE BREAST IMPLANTS - NORMAL POSTOPERATIVE VARIANTS AND DIAGNOSTIC PITFALLS [J].
BERG, WA ;
ANDERSON, ND ;
ZERHOUNI, EA ;
CHANG, BW ;
KUHLMAN, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :575-578
[3]   DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY [J].
BERG, WA ;
CASKEY, CI ;
HAMPER, UM ;
ANDERSON, ND ;
CHANG, BW ;
SHETH, S ;
ZERHOUNI, EA ;
KUHLMAN, JE .
RADIOGRAPHICS, 1993, 13 (06) :1323-1336
[4]   SINGLE-LUMEN AND DOUBLE-LUMEN SILICONE BREAST IMPLANT INTEGRITY - PROSPECTIVE EVALUATION OF MR AND US CRITERIA [J].
BERG, WA ;
CASKEY, CI ;
HAMPER, UM ;
KUHLMAN, JE ;
ANDERSON, ND ;
CHANG, BW ;
SHETH, S ;
ZERHOUNI, EA .
RADIOLOGY, 1995, 197 (01) :45-52
[5]   DEFINITION OF TERMS FOR DESCRIBING LOSS OF GEL FROM BREAST IMPLANTS [J].
DOWDEN, RV .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1360-1360
[6]   DIAGNOSIS OF BREAST IMPLANT RUPTURE - IMAGING FINDINGS AND RELATIVE EFFICACIES OF IMAGING TECHNIQUES [J].
EVERSON, LI ;
PARANTAINEN, H ;
DETLIE, T ;
STILLMAN, AE ;
OLSON, PN ;
LANDIS, G ;
FOSHAGER, MC ;
CUNNINGHAM, B ;
GRIFFITHS, HJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) :57-60
[7]  
Gorczyca D P, 1994, Magn Reson Imaging Clin N Am, V2, P659
[8]   SILICONE BREAST IMPLANTS INVIVO - MR IMAGING [J].
GORCZYCA, DP ;
SINHA, S ;
AHN, CY ;
DEBRUHL, ND ;
HAYES, MK ;
GAUSCHE, VR ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1992, 185 (02) :407-410
[9]   SILICONE BREAST IMPLANT RUPTURES IN AN ANIMAL-MODEL - COMPARISON OF MAMMOGRAPHY, MR-IMAGING, US, AND CT [J].
GORCZYCA, DP ;
DEBRUHL, ND ;
AHN, CY ;
HOYT, A ;
SAYRE, JW ;
NUDELL, PP ;
MCCOMBS, M ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1994, 190 (01) :227-232
[10]   MR-IMAGING OF THE BREAST IN PATIENTS WITH SILICONE-GEL IMPLANTS - SPECTRUM OF FINDINGS [J].
MUND, DF ;
FARRIA, DM ;
GORCZYCA, DP ;
DEBRUHL, ND ;
AHN, CY ;
SHAW, WW ;
BASSETT, LW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) :773-778