Ultrasensitive in-house reverse transcription-competitive PCR for quantitation of HIV-1 RNA in plasma

被引:12
作者
Venturi, G
Ferruzzi, R
Romano, L
Catucci, M
Valensin, PE
Zazzi, M
机构
[1] Univ Siena, Dipartimento Biol Mol, Sez Microbiol, I-53100 Siena, Italy
[2] Azienda Osped Senese, Serv Microbiol & Virol, Siena, Italy
关键词
human immunodeficiency virus; RNA; quantitation; plasma; competitive PCR;
D O I
10.1016/S0166-0934(00)00151-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ultrasensitive version of an 'in-house' reverse transcription-competitive polymerase chain reaction assay described previously for quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in plasma was developed. The increase in sensitivity from 400 to 50 HIV-1 RNA copies/ml was achieved by pelleting virus particles from 1.8 ml plasma by centrifugation prior to RNA extraction, modifying competitor DNA structure and amounts, and redesigning primers. Quantitation of HIV-1 RNA in 130 samples tested previously by the standard assay showed that the two procedures yield comparable results (mean absolute difference, 0.26 +/- 0.20 log) and that the ultrasensitive version detects HIV-1 RNA below the threshold of sensitivity of the standard method. The ultrasensitive 'in-house assay' and the reference QUANTIPLEX HIV-1 RNA 3.0 had the same sensitivity and gave equivalent results (mean absolute difference, 0.19+/-0.11 log), as shown by parallel blinded testing of 47 plasma samples. Titration experiments with reconstructed plasma samples allowed the determination of a dynamic range of 50500 000 HIV-I RNA copies/ml for the 'in-house' system. The interassay coefficient of variation for samples nominally containing 200, 4000 and 80 000 HIV-1 RNA copies/ml were 33.4, 22.9 and 38.2%, respectively. The performance, turnaround time, and cost-effectiveness of this system make it suitable for medium-scale clinical application. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 19 条
[1]  
Aschbacher R, 1999, MICROBIOLOGICA, V22, P1
[2]  
Coste J, 1996, J MED VIROL, V50, P293, DOI 10.1002/(SICI)1096-9071(199612)50:4&lt
[3]  
293::AID-JMV3&gt
[4]  
3.0.CO
[5]  
2-3
[6]   Evaluation of the ultrasensitive Roche Amplicor HIV-1 monitor assay for quantitation of human immunodeficiency virus type I RNA [J].
Erali, M ;
Hillyard, DR .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (03) :792-795
[7]  
Hammer SM, 1996, AIDS, V10, pS1
[8]  
KORBER B, 1997, HUMAN RETROVIRUSES A
[9]   Intra-assay performance characteristics of five assays for quantification of human immunodeficiency virus type 1 RNA in plasma [J].
Lin, HJ ;
Pedneault, L ;
Hollinger, FB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (03) :835-839
[10]   Prognosis in HIV-1 infection predicted by the quantity of virus in plasma [J].
Mellors, JW ;
Rinaldo, CR ;
Gupta, P ;
White, RM ;
Todd, JA ;
Kingsley, LA .
SCIENCE, 1996, 272 (5265) :1167-1170