Diffuse luminance flicker increases retinal vessel diameter in humans

被引:89
作者
Formaz, F
Riva, CE
Geiser, M
机构
[1] INST RECH OPHTALMOL,CH-1950 SION 4,SWITZERLAND
[2] UNIV LAUSANNE,SCH MED,CH-1015 LAUSANNE,SWITZERLAND
[3] ECOLE INGN VALAIS,SION,SWITZERLAND
关键词
retinal diameter; flicker; neuronal activity; retinal blood flow;
D O I
10.1076/ceyr.16.12.1252.5021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To determine retinal vessel diameter variations in response to neuronal activity induced by diffuse luminance flicker. Methods. The diameter of retinal arteries and veins was measured in 9 normal subjects by computer analysis of fundus pictures taken in monochromatic light under normal conditions of illumination and after 1 min of sinusoidally varying diffuse luminance flicker at 10 Hz. Results. The diameter immediately after flicker was significantly larger than the pre-stimulus diameter by 4.2 +/- 2.2% for the retinal arteries and 2.7 +/- 1.7% for the retinal veins (mean +/- SD). Six s after cessation of the flicker, arterial diameter was not significantly different from that of pre-flicker value. Conclusions. Diffuse luminance flicker induces an increase in retinal vessel diameter. This increase most probably reflects an increase in retinal blood flow previously evidenced in humans by the blue field simulation technique. The technique needs to be optimized in terms of flicker parameters, to determine whether flicker-evoked retinal diameter changes could represent a useful clinical measure of the capability of the retinal vascular system to vasodilate.
引用
收藏
页码:1252 / 1257
页数:6
相关论文
共 25 条
[1]  
*AM NAT STAND I, 1976, Z1361ANSI
[2]  
BUERK DG, 1995, INVEST OPHTH VIS SCI, V36, P2216
[3]   VESSEL DIAMETER CHANGES DURING THE CARDIAC CYCLE [J].
CHEN, HC ;
PATEL, V ;
WIEK, J ;
RASSAM, SM ;
KOHNER, EM .
EYE, 1994, 8 :97-103
[4]   DYNAMICS OF REGIONAL CEREBRAL BLOOD-FLOW FOR VARIOUS VISUAL-STIMULI [J].
CONRAD, B ;
KLINGELHOFER, J .
EXPERIMENTAL BRAIN RESEARCH, 1989, 77 (02) :437-441
[5]   EVALUATION OF MICROMETRIC AND MICRODENSITOMETRIC METHODS FOR MEASURING THE WIDTH OF RETINAL VESSEL IMAGES ON FUNDUS PHOTOGRAPHS [J].
DELORI, FC ;
FITCH, KA ;
FEKE, GT ;
DEUPREE, DM ;
WEITER, JJ .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1988, 226 (04) :393-399
[6]  
DEUTSCH TA, 1983, ARCH OPHTHALMOL-CHIC, V101, P1278
[7]   ROLE OF NITRIC-OXIDE IN THE COUPLING OF CEREBRAL BLOOD-FLOW TO NEURONAL ACTIVATION IN RATS [J].
DIRNAGL, U ;
LINDAUER, U ;
VILLRINGER, A .
NEUROSCIENCE LETTERS, 1993, 149 (01) :43-46
[8]   BLOOD-FLOW CHANGES IN HUMAN SOMATOSENSORY CORTEX DURING ANTICIPATED STIMULATION [J].
DREVETS, WC ;
BURTON, H ;
VIDEEN, TO ;
SNYDER, AZ ;
SIMPSON, JR ;
RAICHLE, ME .
NATURE, 1995, 373 (6511) :249-252
[9]   The accurate assessment of changes in retinal vessel diameter using multiple frame electrocardiograph synchronised fundus photography [J].
Dumskyj, MJ ;
Aldington, SJ ;
Dore, CJ ;
Kohner, EM .
CURRENT EYE RESEARCH, 1996, 15 (06) :625-632
[10]  
EATON AM, 1988, INVEST OPHTH VIS SCI, V29, P1258