Calibration transfer of near-infrared spectra based on compression of wavelet coefficients

被引:56
作者
Yoon, JG
Lee, BW
Han, CH
机构
[1] Pohang Univ Sci & Technol, Dept Chem Engn, Pohang 790784, Kyungbuk, South Korea
[2] Pohang Univ Sci & Technol, Ctr Automat Res, Pohang 790784, Kyungbuk, South Korea
关键词
near-infrared spectra; calibration transfer; wavelet transform; data compression; partial least square;
D O I
10.1016/S0169-7439(02)00042-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Near-infrared (NIR) spectrometers are widely used as online analyzers. We propose a transfer algorithm of a calibration model for the near-infrared spectrometer. The method, which is based on direct standardization in the compressed wavelet domain, is called WTDS. Calibration transfer in the compressed wavelet domain permits a reduction in processing time for the analysis of large spectral data sets. A calibration transfer based on a compression of wavelet coefficients offers increased robustness against testing errors, with no significant loss of performance, We select the proper set of wavelet coefficients based on the hard thresholding approach, The WTDS shows an improvement in calibration transfer performance, although wavelet coefficients are compressed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 22 条
[1]   Wavelet denoising of infrared spectra [J].
Alsberg, BK ;
Woodward, AM ;
Winson, MK ;
Rowland, J ;
Kell, DB .
ANALYST, 1997, 122 (07) :645-652
[2]   Variable selection in wavelet regression models [J].
Alsberg, BK ;
Woodward, AM ;
Winson, MK ;
Rowland, JJ ;
Kell, DB .
ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) :29-44
[3]   COMPRESSION OF NTH-ORDER DATA ARRAYS BY B-SPLINES .2. APPLICATION TO 2ND-ORDER FT-IR SPECTRA [J].
ALSBERG, BK ;
NODLAND, E ;
KVALHEIM, OM .
JOURNAL OF CHEMOMETRICS, 1994, 8 (02) :127-145
[4]   Standardisation of near-infrared spectrometric instruments: A review [J].
Bouveresse, E ;
Massart, DL .
VIBRATIONAL SPECTROSCOPY, 1996, 11 (01) :3-15
[5]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[6]   MODIFIED ALGORITHM FOR STANDARDIZATION OF NEAR-INFRARED SPECTROMETRIC INSTRUMENTS [J].
BOUVERESSE, E ;
MASSART, DL ;
DARDENNE, P .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1381-1389
[7]   Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration [J].
Bouveresse, E ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (02) :201-213
[8]   Transfer of calibrations of near-infrared spectra using neural networks [J].
Despagne, F ;
Walczak, B ;
Massart, DL .
APPLIED SPECTROSCOPY, 1998, 52 (05) :732-745
[9]   TRANSFER OF CALIBRATION FUNCTION IN NEAR-INFRARED SPECTROSCOPY [J].
FORINA, M ;
DRAVA, G ;
ARMANINO, C ;
BOGGIA, R ;
LANTERI, S ;
LEARDI, R ;
CORTI, P ;
CONTI, P ;
GIANGIACOMO, R ;
GALLIENA, C ;
BIGONI, R ;
QUARTARI, I ;
SERRA, C ;
FERRI, D ;
LEONI, O ;
LAZZERI, L .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 27 (02) :189-203
[10]   On mass spectrometer instrument standardization and interlaboratory calibration transfer using neural networks [J].
Goodacre, R ;
Timmins, EM ;
Jones, A ;
Kell, DB ;
Maddock, J ;
Heginbothom, ML ;
Magee, JT .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :511-532