Numerical simulation of pressure pulsation effects of a snubber in a CNG station for increasing measurement accuracy

被引:35
作者
Farzaneh-Gord, Mahmood [1 ]
Faramarzi, Mostafa [2 ]
Ahmadi, Mohammad Hossein [2 ]
Sadi, Meisam [3 ]
Shamshirband, Shahaboddin [4 ,5 ]
Mosavi, Amir [6 ,7 ]
Chau, Kwok-wing [8 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, Fac Engn, Mashhad, Razavi Khorasan, Iran
[2] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
[3] Islamic Azad Univ, Dept Mech Engn, Shahrood Branch, Shahrood, Iran
[4] Ton Duc Thang Univ, Dept Management Sci & Technol Dev, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Informat Technol, Ho Chi Minh City, Vietnam
[6] Oxford Brookes Univ, Sch Built Environm, Oxford, England
[7] Obuda Univ, Kando Kalman Fac Elect Engn, Inst Automat, Budapest, Hungary
[8] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
关键词
Snubber; CNG station; pressure pulsation; reciprocating compressor; turbine flow meter; POLLUTANT TRANSPORT MODEL; NATURAL-GAS; FLOW;
D O I
10.1080/19942060.2019.1624197
中图分类号
T [工业技术];
学科分类号
120111 [工业工程];
摘要
Natural companies employ turbine flow meters to measure natural gas which delivered to Compressed Natural Gas stations. The stations utilize compressors to increase pressure. The compressor produces a flow pulsation, which affects the accuracy of the measurement. The main aim of this article is to decrease the compressor effects on measurement accuracy by utilizing a snubber between the turbine flow meter and the reciprocating compressors. For this aim, numerical modeling has been built to simulate natural gas flow through a snubber. The effects of various snubber parameters on pressure pulsation have been investigated. The parameters included snubber volume to the minimum volume ratio, the ratio of height to diameter, outlet pipe length, and the existence and non-existence a buffer. The Ansys Fluent has been used for numerical modeling with transient analysis. Results show that in H/D value of 3, the maximum reduction in the percentage of pressure pulsation drop is about 47% and increasing the outlet pipe length to the 10 times of initial length causes a decrease of about 83% in pressure pulsations. Besides, for the ratio of snubber volume to the minimum volume from 1 to 16.7, the amplitude of pressure pulsations decreases from 4.1% to 0.25%.
引用
收藏
页码:642 / 663
页数:22
相关论文
共 26 条
[1]
Akbar W. A., 2006, P INT C SUST EN TECH, P659
[2]
Akbar W. A., 2006, PRESSURE CHARACTERIS, P341
[3]
Akbar W. A., 2006, STUDY PRESSURE CHARA, P1
[4]
Experimental and computational fluid dynamics-based numerical simulation of using natural gas in a dual-fueled diesel engine [J].
Akbarian, Eivaz ;
Najafi, Bahman ;
Jafari, Mohsen ;
Ardabili, Sina Faizollahzadeh ;
Shamshirband, Shahaboddin ;
Chau, Kwok-wing .
ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2018, 12 (01) :517-534
[5]
Numerical simulation of PV cooling by using single turn pulsating heat pipe [J].
Alizadeh, Hossein ;
Ghasempour, Roghayeh ;
Shafii, Mohammad Behshad ;
Ahmadi, Mohammad Hossein ;
Yan, Wei-Mon ;
Nazari, Mohammad Alhuyi .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 :203-208
[6]
Computational intelligence approach for modeling hydrogen production: a review [J].
Ardabili, Sina Faizollahzadeh ;
Najafi, Bahman ;
Shamshirband, Shahaboddin ;
Bidgoli, Behrouz Minaei ;
Deo, Ravinesh Chand ;
Chau, Kwok-wing .
ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2018, 12 (01) :438-458
[7]
Atkinson K. N., 1992, Flow Measurement and Instrumentation, V3, P167, DOI 10.1016/0955-5986(92)90032-Z
[8]
Three-dimensional pollutant transport model for the Pearl River Estuary [J].
Chau, KW ;
Jiang, YW .
WATER RESEARCH, 2002, 36 (08) :2029-2039
[9]
A three-dimensional pollutant transport model in orthogonal curvilinear and sigma coordinate system for Pearl river estuary [J].
Chau, KW ;
Jiang, YW .
INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2004, 21 (02) :188-198
[10]
Potential use of capillary tube thermal mass flow meters to measure residential natural gas consumption [J].
Farzaneh-Gord, M. ;
Parvizi, S. ;
Arabkoohsar, A. ;
Machado, L. ;
Koury, R. N. N. .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2015, 22 :540-550