Two-dimensional Fourier filtration of acoustic quantification echocardiographic images: Improved reproducibility and accuracy of automated measurements of left ventricular performance

被引:7
作者
Chandra, S
Garcia, MJ
Morehead, A
Thomas, JD
机构
[1] CLEVELAND CLIN FDN,DEPT CARDIOL,DIV CARDIOL RES,CARDIOVASC IMAGING CTR,CLEVELAND,OH 44195
[2] DARTMOUTH COLL SCH MED,HANOVER,NH
关键词
D O I
10.1016/S0894-7317(97)70067-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the accuracy of Fourier filtration in removing the high-frequency component of noise from acoustic quantification (AQ) echocardiographic images, we processed 800 parasternal short-axis images obtained from 10 study subjects. M-mode tracings were also obtained and used as gold standard for correlating the results from raw AQ and Fourier-filtered images. Left ventricular short-axis diameters measured from the raw AQ and Fourier-filtered data were compared with the M-mode diameters (r = 0.91, p < 0.001 for raw AQ; and r = 0.96, p < 0.001, for Fourier filtered images). Fractional shortening showed better correlation between Fourier-filtered images and M-mode (r = 0.79, p < 0.03) versus raw AQ and M-mode (r = 0.33, p = 0.46). Beat-to-beat reproducibility was also found to be better for fractional area change (r = 0.82, p = 0.01 versus r = 0.66, p = 0.07), peak area filling rate (r = 0.87, p = 0.004 versus p = 0.62, p = 0.1), and peak area emptying rate (r = 0.99, P < 0.0001 versus r = 0.19, p < 0.7) for Fourier filtered versus raw AQ. Our results indicate that Fourier filtration of AQ data results in more accurate representation of the true endocardial borders.
引用
收藏
页码:310 / 319
页数:10
相关论文
共 30 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   ANALYSIS OF VENTRICULAR SHAPE BY ECHOCARDIOGRAPHY IN NORMAL FETUSES, NEWBORNS, AND INFANTS [J].
AZANCOT, A ;
CAUDELL, TP ;
ALLEN, HD ;
HOROWITZ, S ;
SAHN, DJ ;
STOLL, C ;
THIES, C ;
VALDESCRUZ, LM ;
GOLDBERG, SJ .
CIRCULATION, 1983, 68 (06) :1201-1211
[3]  
BACHARACH SL, 1983, J NUCL MED, V24, P1176
[4]  
BRACEWELL R, 1978, FOURIER TRANSFORM
[5]  
Brigham E.O., 1974, FAST FOURIER TRANSFO
[6]  
Cao Qi-Ling, 1993, Journal of the American College of Cardiology, V21, p275A
[7]   DETECTION, LOCALIZATION, AND ESTIMATION OF EDGES [J].
CHEN, JS ;
MEDIONI, G .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1989, 11 (02) :191-198
[8]  
GARCIA MJ, 1994, J AM SOC ECHOCARDIOG, V7, pS3
[9]   COMPARISON OF LEFT-VENTRICULAR FUNCTION BY ECHOCARDIOGRAPHIC AUTOMATED BORDER DETECTION AND BY RADIONUCLIDE EJECTION FRACTION [J].
GORCSAN, J ;
LAZAR, JM ;
SCHULMAN, DS ;
FOLLANSBEE, WP .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (11) :810-815
[10]   ONLINE QUANTIFICATION OF LEFT-VENTRICULAR FUNCTION BY AUTOMATIC BOUNDARY DETECTION AND ULTRASONIC BACKSCATTER IMAGING [J].
HERREGODS, MC ;
VERMYLEN, J ;
BYNENS, B ;
DEGEEST, H ;
VANDEWERF, F .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (03) :359-362