Assessment of techniques for measuring the ventilation rate, using an experimental building section

被引:37
作者
Demmers, TGM
Burgess, LR
Phillips, VR
Clark, JA
Wathes, CM
机构
[1] Silsoe Res Inst, Silsoe MK45 4HS, Beds, England
[2] Univ Nottingham, Loughborough LE12 5RD, Leics, England
来源
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH | 2000年 / 76卷 / 01期
关键词
D O I
10.1006/jaer.2000.0532
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A full-scale, laboratory building section at Silsoe Research Institute was adapted to simulate cross-ventilating airflow patterns representative of those that develop in naturally ventilated, intensive livestock buildings. In the fully controlled, steady-state environment of the building section, the distribution of aerial pollutants and/or tracers was shown to depend on source location and ventilation rate. No single location within the building showed a consistently representative concentration of tracer that would be suitable for calculating ventilation rate by the constant release tracer method. Estimates of ventilation rate using the constant release tracer method, based on the average concentration of groups of six sampling locations within the building section, ranged from 93 to 119% of the ventilation rate measured using calibrated fan-wheel anemometers placed in the ventilation ducts. The best estimates of ventilation rate were obtained when the tracer concentration was measured at the perimeter (in the outlets and inlets) of the building section-these ranged from 99 to 109% of the ventilation rate measured using the fan-wheel anemometers. Airflow and pollutant distribution in the building section were predicted using computational fluid dynamics (CFD). However, these predictions were of limited help as a tool to select sampling locations within the building section, because the use of CFD requires the selection of parameters which entails verification of predictions against experimental data. Visualization of the airflow by smoke was simpler and more suitable for the present purpose. (C) 2000 Silsoe Research Institute.
引用
收藏
页码:71 / 81
页数:11
相关论文
共 25 条
[1]   INTERPRETATION OF TRACER GAS EXPERIMENTS IN VENTILATION RESEARCH [J].
BARBER, EM ;
OGILVIE, JR .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1984, 30 (01) :57-63
[2]  
BARBER EM, 1982, CAN AGR ENG, V24, P25
[3]  
BARBER EM, 1982, 824551 ASAE
[4]  
BERCKMANS D, 1991, INDOOR AIR, V3, P323
[5]   AIR-FLOW PATTERNS AND TEMPERATURE DISTRIBUTION IN AN EXPERIMENTAL PIGGERY [J].
BOON, CR .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1978, 23 (02) :129-139
[6]  
BOON CR, 1994, 944586 ASAE
[7]   CONFINED SPACE VENTILATION - TRACER GAS-ANALYSIS OF MIXING CHARACTERISTICS [J].
BOWES, SM ;
MASON, EG ;
CORN, M .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1993, 54 (11) :639-646
[8]   VENTILATION INVESTIGATIONS USING A SECTION OF A LIVESTOCK BUILDING AND AIR-FLOW VISUALIZATION BY BUBBLES [J].
CARPENTER, GA ;
RANDALL, JM ;
MOULSLEY, LJ .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1972, 17 (04) :323-+
[9]  
CHOI HL, 1990, T ASAE, V33, P274, DOI 10.13031/2013.31327
[10]  
CHRISTENSEN KS, 1992, P ROOMV 92 AIR DISTR